
CSA C22.2 NO. 201:M84 (R2024)
CSA C22.2 NO. 201:M84 (R2024) – Metal-Enclosed High Voltage Busways
CDN $134.00
Metal-Enclosed High Voltage Busways
Description
Preface This is the first edition of No. 201 of a series of standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. It is written in SI (metric) units. The busways covered by this Standard are indoor and outdoor metal-enclosed busways for voltages from 751 V to 46 kV, inclusive, ac or dc, intended to be used in nonhazardous locations. This Standard was prepared under the jurisdiction of the CSA Standards Steering Committee on CE Code, Part II, and was formally approved by this Committee and its Technical Committee on Industrial Products. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to indoor and outdoor metal-enclosed busways for voltages from 751 V to 46 kV, inclusive, ac or dc, intended to be used in nonhazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I. 1.2 This Standard includes straight bus sections, elbows, tees, adapter boxes, wall flanges, forced-cooled and nonforced-cooled busways, isolating links, and expansion joints. It includes constructions with rigid bus or cable type conductors. *Effective Date – August 31, 1986 1.3 This Standard applies to busways using air as part of the insulation system but excludes gases (other than air) and solid or liquid insulation systems.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
33
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the first edition of No. 201 of a series of standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. It is written in SI (metric) units. The busways covered by this Standard are indoor and outdoor metal-enclosed busways for voltages from 751 V to 46 kV, inclusive, ac or dc, intended to be used in nonhazardous locations. This Standard was prepared under the jurisdiction of the CSA Standards Steering Committee on CE Code, Part II, and was formally approved by this Committee and its Technical Committee on Industrial Products. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to indoor and outdoor metal-enclosed busways for voltages from 751 V to 46 kV, inclusive, ac or dc, intended to be used in nonhazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I. 1.2 This Standard includes straight bus sections, elbows, tees, adapter boxes, wall flanges, forced-cooled and nonforced-cooled busways, isolating links, and expansion joints. It includes constructions with rigid bus or cable type conductors. *Effective Date - August 31, 1986 1.3 This Standard applies to busways using air as part of the insulation system but excludes gases (other than air) and solid or liquid insulation systems.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA E61558-2-13:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-13: Particular requirements and tests for auto-transformers and power supply units incorporating auto-transformers for general applications (Adopted IEC 61558-2-13:2022, third edition, 2022-10, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-13 : Exigences particulières et essais pour les autotransformateurs et les blocs d’alimentation qui incorporent des autotransformateurs pour applications d’ordre général (norme IEC 61558-2-13:2022 adoptée, troisième édition, 2022-10, avec exigences propres au Canada)
CDN $205.00 Add to cart -

CAN/CSA-E60730-2-9:18 (R2023) – Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted IEC 60730-2-9:2018, edition 4:2015 consolidated with amendment 1:2018, with Canadian deviations)
CDN $944.00 Add to cart -

CAN/CSA-E60730-2-9:18 (R2023)/A2:24 – Amendment 2:2024 to CAN/CSA-E60730-2-9:18, Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted amendment 2:2020 to IEC 60730-2-9:2018)
CDN $19.00 Add to cart







