
CSA C22.2 NO. 250.570:24
CSA C22.2 NO. 250.570:24 – Track lighting
CDN $284.00
Track lighting
Description
Preface This is the second edition of CSA C22.2 No. 250.570, Track lighting , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous edition published in 2016. The following are the major changes to this edition: a) simplification and clarification of the Scope (see Clause 1.1); b) revisions for movable joints containing conductors (see Clause 5.12); c) revisions for track adaptors (see Clauses 6.101.6, 17.105.2, 17.105.3, and 17.105.4); d) clarification of track lengths for canopies (see Clauses 6.103.1 and 6.103.2); e) clarification for indoor use only and track luminaires with fluorescent ballasts or metal halide lamps (see Clauses 8, 8.2.1, 9, and 9.3.6); f) removal of duplicate track clip test (see Clauses 17.102 and AA.5.7.2); g) clarification of tests for connectors and end covers, and preserving definitions (see Clauses 17.106, 17.108, 17.110, and 18.101.1); h) additions in accordance with CSA C22.2 No. 250 (see Clauses 6.20 and 10, and Annexes H, J, and K); and i) clause reference renumbering in accordance with CSA C22.2 No. 250.0. This Standard contains specific requirements for track lighting and is intended to be used together with the requirements for luminaires in CSA C22.2 No. 250.0. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface to CSA C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Lighting Products, under the jurisdiction of the Technical Committee on Consumer and Commercial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions The requirements specified in this Standard apply to wall and ceiling-mounted track lighting systems intended to be installed in non-hazardous dry locations in accordance with the Canadian Electrical Code, Part I. These requirements apply to a) permanently installed track systems i) rated 347 V or less, 40 A max; ii) supplied by a power source with an output of 30 Vrms, 42.4 Vpeak, or 60 Vdc, and less than 240 VA; or iii) supplied by a Class 2 power source; b) permanently installed lighting systems employing bare conductors supplied by a power source with an output up to 30 Vrms, 42.4 Vpeak, or 60 Vdc, and less than 240 VA; c) extra-low-voltage suspended ceiling grid systems that operate up to 30 Vrms or 42.4 Vpeak, connected to a Class 2 power source; d) luminaire assemblies incorporating incandescent, fluorescent, light-emitting diodes, and high-intensity discharge lighting sources; and e) canopies and other accessories. Note: See Rule 30-104 of the Canadian Electrical Code, Part I, for the maximum rating of overcurrent protection. 1.2 Dual measurements The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.3 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
67
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the second edition of CSA C22.2 No. 250.570, Track lighting , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous edition published in 2016. The following are the major changes to this edition: a) simplification and clarification of the Scope (see Clause 1.1); b) revisions for movable joints containing conductors (see Clause 5.12); c) revisions for track adaptors (see Clauses 6.101.6, 17.105.2, 17.105.3, and 17.105.4); d) clarification of track lengths for canopies (see Clauses 6.103.1 and 6.103.2); e) clarification for indoor use only and track luminaires with fluorescent ballasts or metal halide lamps (see Clauses 8, 8.2.1, 9, and 9.3.6); f) removal of duplicate track clip test (see Clauses 17.102 and AA.5.7.2); g) clarification of tests for connectors and end covers, and preserving definitions (see Clauses 17.106, 17.108, 17.110, and 18.101.1); h) additions in accordance with CSA C22.2 No. 250 (see Clauses 6.20 and 10, and Annexes H, J, and K); and i) clause reference renumbering in accordance with CSA C22.2 No. 250.0. This Standard contains specific requirements for track lighting and is intended to be used together with the requirements for luminaires in CSA C22.2 No. 250.0. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface to CSA C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Lighting Products, under the jurisdiction of the Technical Committee on Consumer and Commercial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions The requirements specified in this Standard apply to wall and ceiling-mounted track lighting systems intended to be installed in non-hazardous dry locations in accordance with the Canadian Electrical Code, Part I. These requirements apply to a) permanently installed track systems i) rated 347 V or less, 40 A max; ii) supplied by a power source with an output of 30 Vrms, 42.4 Vpeak, or 60 Vdc, and less than 240 VA; or iii) supplied by a Class 2 power source; b) permanently installed lighting systems employing bare conductors supplied by a power source with an output up to 30 Vrms, 42.4 Vpeak, or 60 Vdc, and less than 240 VA; c) extra-low-voltage suspended ceiling grid systems that operate up to 30 Vrms or 42.4 Vpeak, connected to a Class 2 power source; d) luminaire assemblies incorporating incandescent, fluorescent, light-emitting diodes, and high-intensity discharge lighting sources; and e) canopies and other accessories. Note: See Rule 30-104 of the Canadian Electrical Code, Part I, for the maximum rating of overcurrent protection. 1.2 Dual measurements The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.3 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61558-2-5:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units (Adopted IEC 61558-2-5:2024, third edition, 2024-08, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-5 : Exigences particulières et essais pour les transformateurs pour rasoirs, les blocs d’alimentation incorporant un transformateur pour rasoir et les blocs d’alimentation pour rasoirs (norme IEC 61558-2-5:2024 adoptée, troisième édition, 2024-08, avec exigences propres au Canada)
CDN $299.00 Add to cart -

IEEE 844.3-2019/CSA C22.2 NO. 293.3:19 (R2024) – Impedance heating of pipelines and equipment—General, testing, marking, and documentation requirements
CDN $174.00 Add to cart -

CSA E61558-2-13:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-13: Particular requirements and tests for auto-transformers and power supply units incorporating auto-transformers for general applications (Adopted IEC 61558-2-13:2022, third edition, 2022-10, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-13 : Exigences particulières et essais pour les autotransformateurs et les blocs d’alimentation qui incorporent des autotransformateurs pour applications d’ordre général (norme IEC 61558-2-13:2022 adoptée, troisième édition, 2022-10, avec exigences propres au Canada)
CDN $205.00 Add to cart -

CSA E61959:14 (R2024) – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Mechanical tests for sealed portable secondary cells and batteries (Adopted IEC 61959:2004, first edition, 2004-01, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide – Essais mécaniques pour accumulateurs portables étanches (norme CEI 61959:2004 adoptée, première édition, 2004-01, avec exigences propres au Canada)
CDN $56.00 Add to cart







