Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 263:15 (R2025)

CSA C22.2 NO. 263:15 (R2025) – Fire pump controllers (Tri-national standard, with UL 218 and NMX-J-626-ANCE-2015)

CDN $877.00

Fire pump controllers (Tri-national standard, with UL 218 and NMX-J-626-ANCE-2015)

SKU: 2423691 Categories: ,

Description

Preface This is the harmonized ANCE, CSA Group, and UL standard for Fire pump controllers. It is the second edition of NMX-J-626-ANCE, the second edition of CSA C22.2 No. 263, and the third edition of UL 218. This edition of NMX-J-626-ANCE supersedes the previous edition published on September 28, 2009. This edition of CSA C22.2 No. 263 supersedes the previous edition published in 2009. This edition of UL 218 supersedes the previous edition published in 1999. This harmonized standard was prepared by the Association of Standardization and Certification, (ANCE), CSA Group and Underwriters Laboratories Inc. (UL). The efforts and support of the Technical Harmonization Committee for Fire Pump Controllers, CANENA THSC 17B WG4, of the Council on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. This standard is considered suitable for use for conformity assessment within the stated scope of the standard. The present Mexican Standard was developed by the CT 64 Instalaciones eléctricas y protección contra choque eléctrico from the Comite de Normalizacion de la Asociacion de Normalizacion y Certificacion, A.C., CONANCE, with the collaboration of the fire pump controllers manufactures and users. This standard was reviewed by the CSA Subcommittee for Fire Pump Controllers, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard was reviewed and approved by the Committee de Normalizacion of ANCE (CONANCE). This standard was reviewed by UL’s Standards Technical Panel (STP) for Fire Pump Controllers, STP 218. This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 Products covered 1.1.1 These requirements cover controllers intended for starting and stopping centrifugal and positive displacement fire pumps, including automatic and non-automatic types for electric motor with or without transfer switch or engine driven pumps in accordance with Annex A, item 1. Types of controllers covered include diesel engine, electric motor, limited service, medium voltage and residential. Controllers may be suitable for use as service equipment. This equipment is for installation in non-hazardous locations in accordance with Annex A, item 2. 1.1.2 Controllers for electric motor driven, centrifugal fire pumps are intended for use with squirrel cage or wound rotor motors rated 600 V or less. Controllers for squirrel cage motors may be for across-the-line or reduced inrush current starting. Controllers may be provided with integral automatic transfer switches. 1.1.3 Variable speed fire pump controllers for electric motor driven, centrifugal fire pumps are intended for use with squirrel cage induction, inverter duty rated motors rated 600 V or less, and rated for 50 Hz or 60 Hz. 1.1.4 Limited service controllers are intended for across-the-line starting of squirrel cage motors rated 22 kW (30 hp) or less, 600 V or less. Controllers may be provided with integral automatic transfer switches. 1.1.5 Medium voltage fire pump controllers are intended for use with squirrel cage motors rated 601 V – 7.2 kV AC. 1.1.6 Residential fire pump controllers are intended for use with single-phase squirrel cage motors rated 240 V or less. Residential fire pump controllers are intended to be used in one or two family dwelling units in accordance with the requirements of item 35 in Annex A. 1.1.7 Diesel engine fire pump controllers rated nominal 24 V DC or less are intended for use with fire pump engines. Where required, AC voltage is limited to 600 V AC or less. 1.2 Products not covered 1.2.1 An automatic transfer switch intended to be used in fire pump circuits, that is provided separate from a controller. Note: Stand-alone automatic transfer switches for fire pump circuits are covered by the requirements of item 11, Annex A.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

108

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the harmonized ANCE, CSA Group, and UL standard for Fire pump controllers. It is the second edition of NMX-J-626-ANCE, the second edition of CSA C22.2 No. 263, and the third edition of UL 218. This edition of NMX-J-626-ANCE supersedes the previous edition published on September 28, 2009. This edition of CSA C22.2 No. 263 supersedes the previous edition published in 2009. This edition of UL 218 supersedes the previous edition published in 1999. This harmonized standard was prepared by the Association of Standardization and Certification, (ANCE), CSA Group and Underwriters Laboratories Inc. (UL). The efforts and support of the Technical Harmonization Committee for Fire Pump Controllers, CANENA THSC 17B WG4, of the Council on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. This standard is considered suitable for use for conformity assessment within the stated scope of the standard. The present Mexican Standard was developed by the CT 64 Instalaciones eléctricas y protección contra choque eléctrico from the Comite de Normalizacion de la Asociacion de Normalizacion y Certificacion, A.C., CONANCE, with the collaboration of the fire pump controllers manufactures and users. This standard was reviewed by the CSA Subcommittee for Fire Pump Controllers, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard was reviewed and approved by the Committee de Normalizacion of ANCE (CONANCE). This standard was reviewed by UL’s Standards Technical Panel (STP) for Fire Pump Controllers, STP 218. This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 Products covered 1.1.1 These requirements cover controllers intended for starting and stopping centrifugal and positive displacement fire pumps, including automatic and non-automatic types for electric motor with or without transfer switch or engine driven pumps in accordance with Annex A, item 1. Types of controllers covered include diesel engine, electric motor, limited service, medium voltage and residential. Controllers may be suitable for use as service equipment. This equipment is for installation in non-hazardous locations in accordance with Annex A, item 2. 1.1.2 Controllers for electric motor driven, centrifugal fire pumps are intended for use with squirrel cage or wound rotor motors rated 600 V or less. Controllers for squirrel cage motors may be for across-the-line or reduced inrush current starting. Controllers may be provided with integral automatic transfer switches. 1.1.3 Variable speed fire pump controllers for electric motor driven, centrifugal fire pumps are intended for use with squirrel cage induction, inverter duty rated motors rated 600 V or less, and rated for 50 Hz or 60 Hz. 1.1.4 Limited service controllers are intended for across-the-line starting of squirrel cage motors rated 22 kW (30 hp) or less, 600 V or less. Controllers may be provided with integral automatic transfer switches. 1.1.5 Medium voltage fire pump controllers are intended for use with squirrel cage motors rated 601 V – 7.2 kV AC. 1.1.6 Residential fire pump controllers are intended for use with single-phase squirrel cage motors rated 240 V or less. Residential fire pump controllers are intended to be used in one or two family dwelling units in accordance with the requirements of item 35 in Annex A. 1.1.7 Diesel engine fire pump controllers rated nominal 24 V DC or less are intended for use with fire pump engines. Where required, AC voltage is limited to 600 V AC or less. 1.2 Products not covered 1.2.1 An automatic transfer switch intended to be used in fire pump circuits, that is provided separate from a controller. Note: Stand-alone automatic transfer switches for fire pump circuits are covered by the requirements of item 11, Annex A.

Previous Editions

Can’t find what you are looking for?

Please contact us at: