
CSA C22.2 NO. 265:12 (R2022)
CSA C22.2 NO. 265:12 (R2022) – Out of parameter circuit interrupter (OPCI)
CDN $1,251.00
Out of parameter circuit interrupter (OPCI)
Description
Preface This is the first edition of CSA C22.2 No. 265, Out of parameter circuit interrupter (OPCI). It is one of a series of Standards issued under Part II of the Canadian Electrical Code and is written in SI (metric) units. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of the latest edition of CAN/CSA-C22.2 No.0. This Standard was prepared by the Integrated Committee on Wiring Devices, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard covers requirements for devices to detect certain out of parameter conditions of supply voltage and/or load current and mitigate, by circuit interruption, the effects of (a) overload within utilization equipment; or (b) over- or under-voltage, or both that can pose a risk of fire ignition under certain conditions. These devices are to be incorporated in certified (end) products intended for use on alternating current (ac) circuits of 120 V, 60 Hz, up to 20 A in accordance with the Canadian Electrical Code, Part I. 1.2 Devices covered by this Standard are called out of parameter circuit interrupters (OPCI), and there are three types: (a) OPCI-I – an OPCI for overload current within a load; (b) OPCI-V – an OPCI for over or under voltage; and (c) OPCI-VI – an OPCI incorporating both OPCI-I and OPCI-V functions. 1.3 In CSA standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application. 1.4 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
45
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the first edition of CSA C22.2 No. 265, Out of parameter circuit interrupter (OPCI). It is one of a series of Standards issued under Part II of the Canadian Electrical Code and is written in SI (metric) units. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of the latest edition of CAN/CSA-C22.2 No.0. This Standard was prepared by the Integrated Committee on Wiring Devices, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard covers requirements for devices to detect certain out of parameter conditions of supply voltage and/or load current and mitigate, by circuit interruption, the effects of (a) overload within utilization equipment; or (b) over- or under-voltage, or both that can pose a risk of fire ignition under certain conditions. These devices are to be incorporated in certified (end) products intended for use on alternating current (ac) circuits of 120 V, 60 Hz, up to 20 A in accordance with the Canadian Electrical Code, Part I. 1.2 Devices covered by this Standard are called out of parameter circuit interrupters (OPCI), and there are three types: (a) OPCI-I - an OPCI for overload current within a load; (b) OPCI-V - an OPCI for over or under voltage; and (c) OPCI-VI - an OPCI incorporating both OPCI-I and OPCI-V functions. 1.3 In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application. 1.4 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA SPE-3000:19 – Model code for the field evaluation of medical electrical equipment (MEE) and medical electrical systems (MES)
CDN $334.00 Add to cart -

IEEE 844.4-2019/CSA C293.4:19 (R2024) – Impedance heating of pipelines and equipment—Application guide for design, installation, testing, commissioning, and maintenance
CDN $174.00 Add to cart -

CSA E61558-2-5:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-5: Particular requirements and tests for transformers for shavers, power supply units for shavers and shaver supply units (Adopted IEC 61558-2-5:2024, third edition, 2024-08, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-5 : Exigences particulières et essais pour les transformateurs pour rasoirs, les blocs d’alimentation incorporant un transformateur pour rasoir et les blocs d’alimentation pour rasoirs (norme IEC 61558-2-5:2024 adoptée, troisième édition, 2024-08, avec exigences propres au Canada)
CDN $299.00 Add to cart -

CSA SPE-1000:25 – Model Code for the field evaluation of electrical equipment
CDN $378.00 Add to cart







