CSA C22.2 NO. 267:16 (R2026)
CSA C22.2 NO. 267:16 (R2026) – Armoured segmented power and communication assembly (ASPCA)
CDN $197.00
Armoured segmented power and communication assembly (ASPCA)
Description
Preface This is the second edition of CSA C22.2 No. 267, Armoured segmented power and communication assembly (ASPCA) . It is part of a series of Standards issued by CSA Group under the Canadian Electrical Code, Part II. It supersedes the previous edition published in 2015. This new edition contains new information to clarify the installation instructions, establishes the minimum requirements for durability of the marking on the product, and changes some testing references from the CSA 22.2 No 0.3 to CSA C22.2 No 2556 For general information on the Standards of the Canadian Electrical Code, Part II, see the preface to CAN/CSA-C22.2 No. 0, General Requirements — Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Metal Clad Cables ICWC03 under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies the construction and testing of armoured segmented power and communication assembly (ASPCA) composite cable systems suitable for emergency applications intended for installation in accordance with the rules of the Canadian Electrical Code, Part I, on systems having nominal voltages of 600 V or less. Note: Systems can include insulated power conductors, optical fibers, coaxial cables and fittings (connectors and boxes). 1.2 This Standard applies to fire-resistant-rated, armoured, thermally-insulated, strain-relieved, multi- conductor, segmented, power and communications cable systems, rated up to 600 V and intended for use in industrial and commercial applications. 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
38
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the second edition of CSA C22.2 No. 267, Armoured segmented power and communication assembly (ASPCA) . It is part of a series of Standards issued by CSA Group under the Canadian Electrical Code, Part II. It supersedes the previous edition published in 2015. This new edition contains new information to clarify the installation instructions, establishes the minimum requirements for durability of the marking on the product, and changes some testing references from the CSA 22.2 No 0.3 to CSA C22.2 No 2556 For general information on the Standards of the Canadian Electrical Code, Part II, see the preface to CAN/CSA-C22.2 No. 0, General Requirements — Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Metal Clad Cables ICWC03 under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies the construction and testing of armoured segmented power and communication assembly (ASPCA) composite cable systems suitable for emergency applications intended for installation in accordance with the rules of the Canadian Electrical Code, Part I, on systems having nominal voltages of 600 V or less. Note: Systems can include insulated power conductors, optical fibers, coaxial cables and fittings (connectors and boxes). 1.2 This Standard applies to fire-resistant-rated, armoured, thermally-insulated, strain-relieved, multi- conductor, segmented, power and communications cable systems, rated up to 600 V and intended for use in industrial and commercial applications. 1.3 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

IEEE 844.1-2017/CSA C22.2 NO. 293.1:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—General, testing, marking, and documentation requirements
CDN $158.00 Add to cart -

IEEE 844.3-2019/CSA C22.2 NO. 293.3:19 (R2024) – Impedance heating of pipelines and equipment—General, testing, marking, and documentation requirements
CDN $174.00 Add to cart -

IEEE 844.4-2019/CSA C293.4:19 (R2024) – Impedance heating of pipelines and equipment—Application guide for design, installation, testing, commissioning, and maintenance
CDN $174.00 Add to cart -

CSA G12:14 (R2024) – Zinc-coated steel wire strand
CDN $136.00 Add to cart