Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 272:26

CSA C22.2 NO. 272:26 – Wind turbine electrical systems

CDN $299.00

Wind turbine electrical systems

Description

Preface This is the third edition of CSA C22.2 No. 272, Wind turbine electrical systems . It supersedes the previous editions published in 2020 and 2014. It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. The following are the major changes to this edition: a) updated requirements regarding liquid-filled transformers (see Clause 4.2.11.2); b) added standards to the requirements for dry-type transformers (see Clause 4.2.11.3); c) added standards to the requirements for converters/inverters (see Clause 4.2.12); d) added standards to the requirements for motors and generators (see Clause 4.2.20); e) added standards to the requirements for emergency stop buttons (see Clause 9.7.2); f) updated requirements regarding ampacity (see Clause 10.8.1.3); and g) updated requirements regarding electrical qualification of climb assists (see Clause 13.4.1). For general information on the standards of the Canadian Electrical Code, Part II, see the Preface of CSA C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Wind Turbines — Electrical Qualification, under the jurisdiction of the Technical Committee on Wind Turbines and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard applies to complete wind turbine electrical systems and associated electrical equipment intended for connection at not more than 46 kV, and intended for use in accordance with the Canadian Electrical Code, Part I. Products covered by the scope of this Standard are subject to the requirements of CSA C22.2 No. 0. 1.2 Application This Standard applies to wind turbines of all sizes. 1.3 Exclusions This Standard does not apply to performance with respect to grid codes or to power performance of wind turbines. Note: Information on test methods for power performance of wind turbines can be found in CAN/CSA-IEC 61400-12-1 and IEC 61400-12-2. 1.4 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

72

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the third edition of CSA C22.2 No. 272, Wind turbine electrical systems . It supersedes the previous editions published in 2020 and 2014. It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. The following are the major changes to this edition: a) updated requirements regarding liquid-filled transformers (see Clause 4.2.11.2); b) added standards to the requirements for dry-type transformers (see Clause 4.2.11.3); c) added standards to the requirements for converters/inverters (see Clause 4.2.12); d) added standards to the requirements for motors and generators (see Clause 4.2.20); e) added standards to the requirements for emergency stop buttons (see Clause 9.7.2); f) updated requirements regarding ampacity (see Clause 10.8.1.3); and g) updated requirements regarding electrical qualification of climb assists (see Clause 13.4.1). For general information on the standards of the Canadian Electrical Code, Part II, see the Preface of CSA C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Wind Turbines — Electrical Qualification, under the jurisdiction of the Technical Committee on Wind Turbines and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard applies to complete wind turbine electrical systems and associated electrical equipment intended for connection at not more than 46 kV, and intended for use in accordance with the Canadian Electrical Code, Part I. Products covered by the scope of this Standard are subject to the requirements of CSA C22.2 No. 0. 1.2 Application This Standard applies to wind turbines of all sizes. 1.3 Exclusions This Standard does not apply to performance with respect to grid codes or to power performance of wind turbines. Note: Information on test methods for power performance of wind turbines can be found in CAN/CSA-IEC 61400-12-1 and IEC 61400-12-2. 1.4 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Previous Editions

Can’t find what you are looking for?

Please contact us at: