
CSA C22.2 NO. 27:25
CSA C22.2 NO. 27:25 – Busways (Tri-national standard, with UL 857 and NMX-J-148-ANCE)
CDN $1,133.00
Busways (Tri-national standard, with UL 857 and NMX-J-148-ANCE)
Description
Preface This is the harmonized ANCE, CSA Group, and ULSE standard for Busways . It is the fourth edition of NMX-J-148-ANCE, the seventh edition of CSA C22.2 No. 27, and the fourteenth edition of UL 857. This edition of NMX-J-148-ANCE supersedes the previous edition published on December 9, 2011. This edition of CSA C22.2 No. 27 supersedes the previous edition published on March 25, 2009. This edition of UL 857 supersedes the previous edition published on April 9, 2021. This harmonized standard was prepared by the Association of Standardization and Certification (ANCE), CSA Group, and ULSE. The efforts and support of the Technical Harmonization Committee for Connectors, of the Council on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. The present Mexican Standard was developed by the CT CDI from the Comite de Normalizacion de la Asociacion de Normalizacion y Certificacion, A.C., CONANCE, with the collaboration of the busway manufacturers and users. This Standard was reviewed by the CSA Subcommittee on Busways, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to service-entrance, feeder, and branch-circuit busways and associated fittings rated at 1000 V or less, 6000 A or less, and intended for use in accordance with the Canadian Electrical Code, Part I (CE Code, Part I), NFPA 70®, National Electrical Code® (NEC®), and the Mexican Standard for Electrical Installations (Utility), NOM-001-SEDE. These requirements do not apply to metal enclosed bus intended for connecting switchgear assemblies for use in prefabricated electric distribution systems. NFPA 70®, National Electrical Code®, and NEC® are registered trademarks of the National Fire Protection Association, Quincy, MA. 1.2 For the purpose of these requirements, a busway is considered to be a grounded metal enclosure containing factory-mounted conductors that are usually copper or aluminum bars, rods, or tubes. 1.3 Requirements stated throughout this Standard for fittings apply to tap boxes, feed boxes, plug-in devices, and similar fittings, but do not apply to busway elbows, tees, and crosses.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
102
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the harmonized ANCE, CSA Group, and ULSE standard for Busways . It is the fourth edition of NMX-J-148-ANCE, the seventh edition of CSA C22.2 No. 27, and the fourteenth edition of UL 857. This edition of NMX-J-148-ANCE supersedes the previous edition published on December 9, 2011. This edition of CSA C22.2 No. 27 supersedes the previous edition published on March 25, 2009. This edition of UL 857 supersedes the previous edition published on April 9, 2021. This harmonized standard was prepared by the Association of Standardization and Certification (ANCE), CSA Group, and ULSE. The efforts and support of the Technical Harmonization Committee for Connectors, of the Council on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. The present Mexican Standard was developed by the CT CDI from the Comite de Normalizacion de la Asociacion de Normalizacion y Certificacion, A.C., CONANCE, with the collaboration of the busway manufacturers and users. This Standard was reviewed by the CSA Subcommittee on Busways, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to service-entrance, feeder, and branch-circuit busways and associated fittings rated at 1000 V or less, 6000 A or less, and intended for use in accordance with the Canadian Electrical Code, Part I (CE Code, Part I), NFPA 70®, National Electrical Code® (NEC®), and the Mexican Standard for Electrical Installations (Utility), NOM-001-SEDE. These requirements do not apply to metal enclosed bus intended for connecting switchgear assemblies for use in prefabricated electric distribution systems. NFPA 70®, National Electrical Code®, and NEC® are registered trademarks of the National Fire Protection Association, Quincy, MA. 1.2 For the purpose of these requirements, a busway is considered to be a grounded metal enclosure containing factory-mounted conductors that are usually copper or aluminum bars, rods, or tubes. 1.3 Requirements stated throughout this Standard for fittings apply to tap boxes, feed boxes, plug-in devices, and similar fittings, but do not apply to busway elbows, tees, and crosses.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-E60730-2-9:18 (R2023)/A2:24 – Amendment 2:2024 to CAN/CSA-E60730-2-9:18, Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted amendment 2:2020 to IEC 60730-2-9:2018)
CDN $19.00 Add to cart -

CAN/CSA-E61558-1:12 (R2022) – Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues – Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada)
CDN $630.00 Add to cart -

IEEE 844.3-2019/CSA C22.2 NO. 293.3:19 (R2024) – Impedance heating of pipelines and equipment—General, testing, marking, and documentation requirements
CDN $174.00 Add to cart -

CSA C22.3 NO. 5.1:93 (R2022) – Recommended practices for electrical protection – Electric contact between overhead supply and communication lines
CDN $149.00 Add to cart







