
CSA C22.2 NO. 60079-5:16 (R2026)
CSA C22.2 NO. 60079-5:16 (R2026) – Explosive atmospheres – Part 5: Equipment protection by powder filling “q” (Adopted IEC 60079-5:2015, fourth edition, 2015-02, with Canadian deviations)
CDN $236.00
Explosive atmospheres – Part 5: Equipment protection by powder filling “q” (Adopted IEC 60079-5:2015, fourth edition, 2015-02, with Canadian deviations)
Description
CSA Preface This is the second edition of CAN/CSA-C22.2 No. 60079-5, Explosive atmospheres — Part 5: Equipment protection by powder filling “q”, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60079-5 (fourth edition, 2015-02). It supersedes the previous edition published in 2011 as CAN/CSA-C22.2 No. 60079-5 (adopted IEC 60079-5:2007). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as “CAN/CSA-C22.2 No. 60079-5” throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60079-0, Explosive atmospheres — Part 0: Equipment — General requirements. Changes in this edition include the removal of Canadian deviations that are no longer applicable. The fourth edition of the IEC Standard includes the following changes: a) relaxation introduced to permit reduced distances through filling material; b) relaxation introduced to permit use of the creepage dimensions of IEC 60079-7 under certain conditions; and c) the addition of a batch routine test. This Standard was reviewed for Canadian adoption by the CSA Integrated Committee on Hazardous Location Products, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 60079 contains specific requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components in the type of protection powder filling “q”, intended for use in explosive gas atmospheres. NOTE 1 Electrical equipment and Ex components protected by powder filling “q” can contain electronic circuits, transformers, protection fuses, relays, intrinsically safe electrical apparatus, associated electrical apparatus, switches, etc. NOTE 2 Type of protection powder filling “q” provides Equipment Protection Level (EPL) Gb or Mb. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This standard applies to electrical equipment, parts of electrical equipment and Ex components with: – a rated supply current less than or equal to 16 A; – a rated supply voltage less than or equal to 1 000 V; – a rated power consumption less than or equal to 1 000 W. ——————————————————————————————————————————– Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C22.2 nº 60079-5, Atmosphères explosives — Partie 5 : Protection du matériel par remplissage pulvérulent «q» . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60079-5 (quatrième édition, 2015-02) qui porte le même titre. Il remplace l’édition antérieure, publiée en 2011 qui portait la désignation CAN/CSA-C22.2 nº 60079-5 (norme IEC 60079-5:2007 adoptée). Il fait partie d’une série de normes publiées par le Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-C22.2 nº 60079-5». Cette norme est conçue pour être utilisée de concert avec la CAN/CSA-C22.2 nº 60079-0, Atmosphères explosives — Partie 0 : Matériel — Exigences générales. Parmi les changements apportés à cette édition, il y a le retrait des exigences propres au Canada qui ne sont plus applicables. Voici les principaux changements apportés à la quatrième édition de la norme IEC : a) un assouplissement des exigences qui a été introduit pour autoriser des distances réduites entre matériaux de remplissage ; b) un assouplissement des exigences qui a été introduit pour autoriser l’utilisation des lignes de fuite dans certaines conditions selon la norme IEC 60079-7 ; et c) l’ajout d’un essai individuel par lot. Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption au Canada par le Comité intégré CSA sur les produits pour emplacements dangereux, sous l’autorité du Comité technique CSA sur les produits industriels et le Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité, et a été officiellement approuvée par le Comité technique. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application La présente partie de l’IEC 60079 contient les exigences spécifiques de construction, d’essais et de marquage d’appareil électrique, des parties d’appareil électrique et des composants Ex à remplissage pulvérulent, mode de protection “q”, destinés à être utilisés dans des atmosphères explosives gazeuses. NOTE 1 L’appareil électrique à remplissage pulvérulent, mode de protection “q” et les composants Ex peuvent contenir des circuits électroniques, des transformateurs, des fusibles de protection, des relais, des matériels électriques de sécurité intrinsèque, des matériels électriques associés, des interrupteurs, etc. NOTE 2 Le mode de protection par remplissage pulvérulent “q” procure un Niveau de Protection du Matériel (EPL1) Gb ou Mb. La présente norme complète et modifie les exigences générales de l’IEC 60079-0. Lorsqu’une exigence de la présente norme diverge d’une exigence de l’IEC 60079-0, l’exigence de cette norme prévaut. La présente norme s’applique aux appareils électriques, aux parties d’appareil électrique et aux composants Ex avec: – un courant assigné d’alimentation inférieur ou égal à 16 A; – une tension assignée d’alimentation inférieure ou égale à 1 000 V; – une puissance consommée assignée inférieure ou égale à 1 000 W.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
71
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CAN/CSA-C22.2 No. 60079-5, Explosive atmospheres — Part 5: Equipment protection by powder filling "q", which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60079-5 (fourth edition, 2015-02). It supersedes the previous edition published in 2011 as CAN/CSA-C22.2 No. 60079-5 (adopted IEC 60079-5:2007). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CAN/CSA-C22.2 No. 60079-5" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60079-0, Explosive atmospheres — Part 0: Equipment — General requirements. Changes in this edition include the removal of Canadian deviations that are no longer applicable. The fourth edition of the IEC Standard includes the following changes: a) relaxation introduced to permit reduced distances through filling material; b) relaxation introduced to permit use of the creepage dimensions of IEC 60079-7 under certain conditions; and c) the addition of a batch routine test. This Standard was reviewed for Canadian adoption by the CSA Integrated Committee on Hazardous Location Products, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 60079 contains specific requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components in the type of protection powder filling "q", intended for use in explosive gas atmospheres. NOTE 1 Electrical equipment and Ex components protected by powder filling "q" can contain electronic circuits, transformers, protection fuses, relays, intrinsically safe electrical apparatus, associated electrical apparatus, switches, etc. NOTE 2 Type of protection powder filling "q" provides Equipment Protection Level (EPL) Gb or Mb. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This standard applies to electrical equipment, parts of electrical equipment and Ex components with: – a rated supply current less than or equal to 16 A; – a rated supply voltage less than or equal to 1 000 V; – a rated power consumption less than or equal to 1 000 W. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C22.2 nº 60079-5, Atmosphères explosives — Partie 5 : Protection du matériel par remplissage pulvérulent «q» . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60079-5 (quatrième édition, 2015-02) qui porte le même titre. Il remplace l’édition antérieure, publiée en 2011 qui portait la désignation CAN/CSA-C22.2 nº 60079-5 (norme IEC 60079-5:2007 adoptée). Il fait partie d’une série de normes publiées par le Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-C22.2 nº 60079-5». Cette norme est conçue pour être utilisée de concert avec la CAN/CSA-C22.2 nº 60079-0, Atmosphères explosives — Partie 0 : Matériel — Exigences générales. Parmi les changements apportés à cette édition, il y a le retrait des exigences propres au Canada qui ne sont plus applicables. Voici les principaux changements apportés à la quatrième édition de la norme IEC : a) un assouplissement des exigences qui a été introduit pour autoriser des distances réduites entre matériaux de remplissage ; b) un assouplissement des exigences qui a été introduit pour autoriser l’utilisation des lignes de fuite dans certaines conditions selon la norme IEC 60079-7 ; et c) l’ajout d’un essai individuel par lot. Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption au Canada par le Comité intégré CSA sur les produits pour emplacements dangereux, sous l’autorité du Comité technique CSA sur les produits industriels et le Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité, et a été officiellement approuvée par le Comité technique. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d'application La présente partie de l’IEC 60079 contient les exigences spécifiques de construction, d'essais et de marquage d'appareil électrique, des parties d'appareil électrique et des composants Ex à remplissage pulvérulent, mode de protection "q", destinés à être utilisés dans des atmosphères explosives gazeuses. NOTE 1 L'appareil électrique à remplissage pulvérulent, mode de protection "q" et les composants Ex peuvent contenir des circuits électroniques, des transformateurs, des fusibles de protection, des relais, des matériels électriques de sécurité intrinsèque, des matériels électriques associés, des interrupteurs, etc. NOTE 2 Le mode de protection par remplissage pulvérulent "q" procure un Niveau de Protection du Matériel (EPL1) Gb ou Mb. La présente norme complète et modifie les exigences générales de l’IEC 60079-0. Lorsqu’une exigence de la présente norme diverge d’une exigence de l’IEC 60079-0, l’exigence de cette norme prévaut. La présente norme s'applique aux appareils électriques, aux parties d'appareil électrique et aux composants Ex avec: – un courant assigné d'alimentation inférieur ou égal à 16 A; – une tension assignée d'alimentation inférieure ou égale à 1 000 V; – une puissance consommée assignée inférieure ou égale à 1 000 W.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-E61558-1:12 (R2022) – Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues – Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada)
CDN $630.00 Add to cart -

CSA SPE-3000:19 – Model code for the field evaluation of medical electrical equipment (MEE) and medical electrical systems (MES)
CDN $334.00 Add to cart -

CAN/CSA-E60730-2-9:18 (R2023)/A2:24 – Amendment 2:2024 to CAN/CSA-E60730-2-9:18, Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted amendment 2:2020 to IEC 60730-2-9:2018)
CDN $19.00 Add to cart -

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart







