Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 77:14 (R2024)

CSA C22.2 NO. 77:14 (R2024) – Motors with inherent overheating protection

CDN $276.00

Motors with inherent overheating protection

SKU: 2423225 Categories: ,

Description

Preface This is the eighth edition of CSA C22.2 No. 77, Motors with inherent overheating protection , part of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 1995, 1988, 1976, 1972, 1970, 1957, and 1942. The major changes in this edition are as follows: a) Clause 5.5 on motors with electronic protection has been added; b) Clause 6.4.5.2 on temperature classes has been clarified; c) the previous Clause 6.6.6 on motors with thermal cutoffs has been deleted; d) Clause 6.10 on reliability of electronic protection circuit has been added; and e) an item addressing electronic protection has been added to Clause 7.1. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CSA CAN/CSA-C22.2 No. 0, General Requirements – Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by a Subcommittee on Motors and Generators, under the jurisdiction of Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has formally been approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to ac and dc motors with inherent overheating protection designed to be used in accordance with the Canadian Electrical Code, Part I, as follows: a) motors with a voltage rating not exceeding 600 V and with a protective device connected in the motor circuit; b) impedance-protected motors with a voltage rating not exceeding 600 V; and c) motors with a voltage rating not exceeding 5000 V and having a protective device connected in an external control circuit with a voltage rating not exceeding 600 V. 1.2 This Standard applies to motors with protective devices that are responsive to a) motor temperature alone; or b) motor temperature and motor current passing through the device but does not apply to motors with protective devices that are responsive to current alone. 1.3 This Standard does not apply to sealed (hermetic) type motor compressors with inherent overheating protection (see CSA C22.2 No. 140.2). 1.4 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

30

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the eighth edition of CSA C22.2 No. 77, Motors with inherent overheating protection , part of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 1995, 1988, 1976, 1972, 1970, 1957, and 1942. The major changes in this edition are as follows: a) Clause 5.5 on motors with electronic protection has been added; b) Clause 6.4.5.2 on temperature classes has been clarified; c) the previous Clause 6.6.6 on motors with thermal cutoffs has been deleted; d) Clause 6.10 on reliability of electronic protection circuit has been added; and e) an item addressing electronic protection has been added to Clause 7.1. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CSA CAN/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by a Subcommittee on Motors and Generators, under the jurisdiction of Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has formally been approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to ac and dc motors with inherent overheating protection designed to be used in accordance with the Canadian Electrical Code, Part I, as follows: a) motors with a voltage rating not exceeding 600 V and with a protective device connected in the motor circuit; b) impedance-protected motors with a voltage rating not exceeding 600 V; and c) motors with a voltage rating not exceeding 5000 V and having a protective device connected in an external control circuit with a voltage rating not exceeding 600 V. 1.2 This Standard applies to motors with protective devices that are responsive to a) motor temperature alone; or b) motor temperature and motor current passing through the device but does not apply to motors with protective devices that are responsive to current alone. 1.3 This Standard does not apply to sealed (hermetic) type motor compressors with inherent overheating protection (see CSA C22.2 No. 140.2). 1.4 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: