Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 85:14 (R2023)

CSA C22.2 NO. 85:14 (R2023) – Rigid PVC boxes and fittings

CDN $174.00

Rigid PVC boxes and fittings

SKU: 2422721 Categories: ,

Description

Preface This is the second edition of CSA C22.2 No. 85, Rigid PVC boxes and fittings , one of a series of Standards issued under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 1989 and 1968. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to rigid unplasticized poly (vinyl chloride)* boxes and fittings of the following types that are intended to be installed and used with rigid PVC conduit at a maximum working temperature of 75 °C in accordance with the rules of the Canadian Electrical Code, Part I: a) junction boxes with an interior volume of 1640 mL+ or less that are intended to provide access to wiring and to enclose splices and taps but not to support wiring devices; b) conduit boxes with an interior volume of 1640 mL+ or less that are intended to be used as pull boxes but not to enclose splices and taps or support wiring devices; c) surface mounted device boxes with an interior volume of 1640 mL+ or less that are intended primarily to support wiring devices but may also be used as a pull box or to enclose wiring joints; d) box covers of the blank and device types; e) expansion joints that are intended to compensate for the linear expansion of a span of rigid PVC conduit; f) junction box terminal adapters that are intended to connect a length of PVC conduit by an elbow or other bend to a box; g) female adapters that are intended to connect a length of PVC conduit to a length of rigid metal conduit; h) reducers that are intended to connect lengths of two different sizes of rigid PVC conduit; i) caps that are intended to close the ends of unused lengths of rigid PVC conduit; and j) bell ends that are intended to provide a bushed opening at the open end of a length of rigid PVC conduit. * For convenience, the shorter term PVC is used in this Standard. + 1640 mL is the volume of trade size known as 100 cubic inches. 1.2 General requirements applicable to this Standard are given in CSA C22.2 No. 0, General Requirements – Canadian Electrical Code, Part II. 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

37

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CSA C22.2 No. 85, Rigid PVC boxes and fittings , one of a series of Standards issued under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 1989 and 1968. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to rigid unplasticized poly (vinyl chloride)* boxes and fittings of the following types that are intended to be installed and used with rigid PVC conduit at a maximum working temperature of 75 °C in accordance with the rules of the Canadian Electrical Code, Part I: a) junction boxes with an interior volume of 1640 mL+ or less that are intended to provide access to wiring and to enclose splices and taps but not to support wiring devices; b) conduit boxes with an interior volume of 1640 mL+ or less that are intended to be used as pull boxes but not to enclose splices and taps or support wiring devices; c) surface mounted device boxes with an interior volume of 1640 mL+ or less that are intended primarily to support wiring devices but may also be used as a pull box or to enclose wiring joints; d) box covers of the blank and device types; e) expansion joints that are intended to compensate for the linear expansion of a span of rigid PVC conduit; f) junction box terminal adapters that are intended to connect a length of PVC conduit by an elbow or other bend to a box; g) female adapters that are intended to connect a length of PVC conduit to a length of rigid metal conduit; h) reducers that are intended to connect lengths of two different sizes of rigid PVC conduit; i) caps that are intended to close the ends of unused lengths of rigid PVC conduit; and j) bell ends that are intended to provide a bushed opening at the open end of a length of rigid PVC conduit. * For convenience, the shorter term PVC is used in this Standard. + 1640 mL is the volume of trade size known as 100 cubic inches. 1.2 General requirements applicable to this Standard are given in CSA C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II. 1.3 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: