
CSA C227.4:21 (R2026)
CSA C227.4:21 (R2026) – Three-phase, pad-mounted distribution transformers with separable insulated high-voltage connectors
CDN $236.00
Three-phase, pad-mounted distribution transformers with separable insulated high-voltage connectors
Description
Preface This is the third edition of CSA C227.4, Three-phase, pad-mounted distribution transformers with separable insulated high-voltage connectors. It supersedes the previous editions published in 2006 and 1978. The major changes in this edition include the following: a) expanded scope to include 34.5 kV system nominal voltage, and discontinued use of the terms “insulation class” and “preferred voltages”; b) updated references to other industry standards; c) clarified requirements with off-circuit voltage taps and added informative note on dual-voltage transformers with taps; d) added requirements to the optional load break switch ratings since previous IEEE references are obsolete; e) modified and clarified requirements with the two-fuse system, also removing tables with manufacturer specific part numbers; f) improved routine test requirements to better align with IEEE. For example, no-load losses and exciting current will be at 100% rated voltage instead of 105%; g) added no internal fuse warning markings; h) clarified and expanded additional optional items in Clause 10. For example, routine partial discharge testing has been added based on the experience and procedures of users; i) the continued inclusion of the electrical characteristics that apply to the transformers covered by this Standard, which were previously provided in CAN/CSA-C2; and j) added Clause B.5.3.1.1 to explain the removal of fusing tables. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies the requirements for three-phase, pad-mounted distribution transformers, consisting of a transformer and a cable entrance compartment with provision for separable insulated high-voltage connectors, intended primarily for operation by electric utilities on three-phase underground distribution systems having primary voltages as shown in Clause 4.6. 1.2 This Standard applies to three-phase, 60 Hz, pad-mounted, liquid-filled distribution transformers, rated at 3000 kVA or below, up to 34.5 kV system nominal voltage, and with separable insulated high-voltage connectors. The transformers are suitable for mounting outdoors on pads without additional protective enclosures. 1.3 This Standard includes voltage ratings, kVA ratings, certain mechanical characteristics, and test procedures. The Standard also includes the following performance characteristics: energy efficiency (in accordance with CAN/CSA-C802.1), temperature rise, loading capabilities, audible sound level, and radio influence voltage (RIV). 1.4 When this equipment is intended for operation by other than an electric utility, it is the purchaser’s responsibility to ensure that the unit meets the requirements of the appropriate electrical inspection authority. 1.5 This Standard allows for the interchangeability of a dead-front, pad-mounted unit by another of the same basic physical size from a different manufacturer for transformers rated 125 kV BIL and below, without modifications to cables or pad. This Standard covers terminal arrangements for both radial and loop-feed systems, including certain minimum dimensions and certain specific dimensions. 1.6 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
74
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the third edition of CSA C227.4, Three-phase, pad-mounted distribution transformers with separable insulated high-voltage connectors. It supersedes the previous editions published in 2006 and 1978. The major changes in this edition include the following: a) expanded scope to include 34.5 kV system nominal voltage, and discontinued use of the terms "insulation class" and "preferred voltages"; b) updated references to other industry standards; c) clarified requirements with off-circuit voltage taps and added informative note on dual-voltage transformers with taps; d) added requirements to the optional load break switch ratings since previous IEEE references are obsolete; e) modified and clarified requirements with the two-fuse system, also removing tables with manufacturer specific part numbers; f) improved routine test requirements to better align with IEEE. For example, no-load losses and exciting current will be at 100% rated voltage instead of 105%; g) added no internal fuse warning markings; h) clarified and expanded additional optional items in Clause 10. For example, routine partial discharge testing has been added based on the experience and procedures of users; i) the continued inclusion of the electrical characteristics that apply to the transformers covered by this Standard, which were previously provided in CAN/CSA-C2; and j) added Clause B.5.3.1.1 to explain the removal of fusing tables. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies the requirements for three-phase, pad-mounted distribution transformers, consisting of a transformer and a cable entrance compartment with provision for separable insulated high-voltage connectors, intended primarily for operation by electric utilities on three-phase underground distribution systems having primary voltages as shown in Clause 4.6. 1.2 This Standard applies to three-phase, 60 Hz, pad-mounted, liquid-filled distribution transformers, rated at 3000 kVA or below, up to 34.5 kV system nominal voltage, and with separable insulated high-voltage connectors. The transformers are suitable for mounting outdoors on pads without additional protective enclosures. 1.3 This Standard includes voltage ratings, kVA ratings, certain mechanical characteristics, and test procedures. The Standard also includes the following performance characteristics: energy efficiency (in accordance with CAN/CSA-C802.1), temperature rise, loading capabilities, audible sound level, and radio influence voltage (RIV). 1.4 When this equipment is intended for operation by other than an electric utility, it is the purchaser’s responsibility to ensure that the unit meets the requirements of the appropriate electrical inspection authority. 1.5 This Standard allows for the interchangeability of a dead-front, pad-mounted unit by another of the same basic physical size from a different manufacturer for transformers rated 125 kV BIL and below, without modifications to cables or pad. This Standard covers terminal arrangements for both radial and loop-feed systems, including certain minimum dimensions and certain specific dimensions. 1.6 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

IEEE 844.2-2017/CSA C293.2:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—Application guide for design, installation, testing, commissioning, and maintenance
CDN $158.00 Add to cart -

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart -

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA SPE-3000:19 – Model code for the field evaluation of medical electrical equipment (MEE) and medical electrical systems (MES)
CDN $334.00 Add to cart







