Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA C22.2 NO. 0:20 (R2025) – General requirements — Canadian Electrical Code, Part II

$

331

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C22.2 NO. 0.12:19 (R2024) – Wiring space and wire bending space in enclosures

$

178

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C22.2 NO. 0.17:22 – Evaluation of properties of polymeric materials

$

315

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C22.2 NO. 0.1:19 (R2024) – General requirements for double-insulated equipment

$

177

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C22.2 NO. 0.15:15 (R2025) – Adhesive labels

$

164

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C22.2 NO. 0.19:10 (R2025) – Requirements for service entrance equipment

$

134

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C22.2 NO. 0.2:16 (R2025) – Insulation coordination

$

164

BUY NOW

CSA C296:19 (R2023)

CSA C296:19 (R2023) – Energy performance of walk-in freezer and walk-in cooler components

CDN $244.00

Energy performance of walk-in freezer and walk-in cooler components

SKU: 2426554 Categories: ,

Description

Preface This is the first edition of CSA C296, Energy performance of walk-in freezer and walk-in cooler components. This Standard specifies the methods used to measure the energy consumption of walk-in freezers and walk-in coolers components. This Standard has harmonized with testing and evaluating the energy efficiency of walk-in freezers and walk-in coolers specified in the United States Department of Energy (DOE) publication Title 10 Code of Federal Regulations (CFR), Part 431, subpart R – Walk-in Coolers and Walk-in Freezers, as published as of December 28, 2016, per the Canada-U.S. Regulatory Cooperation Council (RCC) initiative. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of Natural Resources Canada (NRCan), BC Hydro, Manitoba Hydro, Hydro Québec, Nova Scotia Department of Energy, EfficiencyOne, and Sask Power. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Harmonization Task Group on Walk-in Coolers and Walk-in Freezers, under the jurisdiction of the Technical Committee on Heating, Ventilation, Air Conditioning and Refrigeration and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to walk-in coolers and walk-in freezers (i.e., an enclosed refrigerated storage space that can be walked into) having a total chilled storage area of less than 278.71 m2 (3000 ft2). 1.2 This Standard does not apply to commercial refrigeration appliances covered under CAN/CSA-C657. 1.3 Energy performance evaluation of a walk-in cooler and walk-in freezer is done by evaluating energy performance of the principal components individually that make up a walk-in. This Standard applies to the following walk-in cooler and walk-in freezer components: a) display doors; b) non-display doors; c) non-display panels; and d) refrigeration systems. 1.4 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 The values given in SI (metric) units are the standard. The values given in parentheses are for information only.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

45

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of CSA C296, Energy performance of walk-in freezer and walk-in cooler components. This Standard specifies the methods used to measure the energy consumption of walk-in freezers and walk-in coolers components. This Standard has harmonized with testing and evaluating the energy efficiency of walk-in freezers and walk-in coolers specified in the United States Department of Energy (DOE) publication Title 10 Code of Federal Regulations (CFR), Part 431, subpart R – Walk-in Coolers and Walk-in Freezers, as published as of December 28, 2016, per the Canada-U.S. Regulatory Cooperation Council (RCC) initiative. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of Natural Resources Canada (NRCan), BC Hydro, Manitoba Hydro, Hydro Québec, Nova Scotia Department of Energy, EfficiencyOne, and Sask Power. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Harmonization Task Group on Walk-in Coolers and Walk-in Freezers, under the jurisdiction of the Technical Committee on Heating, Ventilation, Air Conditioning and Refrigeration and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to walk-in coolers and walk-in freezers (i.e., an enclosed refrigerated storage space that can be walked into) having a total chilled storage area of less than 278.71 m2 (3000 ft2). 1.2 This Standard does not apply to commercial refrigeration appliances covered under CAN/CSA-C657. 1.3 Energy performance evaluation of a walk-in cooler and walk-in freezer is done by evaluating energy performance of the principal components individually that make up a walk-in. This Standard applies to the following walk-in cooler and walk-in freezer components: a) display doors; b) non-display doors; c) non-display panels; and d) refrigeration systems. 1.4 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 The values given in SI (metric) units are the standard. The values given in parentheses are for information only.

Previous Editions

Can’t find what you are looking for?

Please contact us at: