Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA C22.6 NO. 1:11 (R2025) – Electrical inspection code for existing residential occupancies

$

216

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C282 LOGBOOK:25 – Emergency electrical power supply for buildings maintenance logbook

$

205

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C225:20 (R2025) – Vehicle-mounted aerial devices

$

218

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C227.5:08 (R2023) – Three-phase live-front pad-mounted distribution transformers

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

C282-15 – Emergency electrical power supply for buildings

$

354

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C235:19 (R2025) – Preferred voltage levels for AC systems up to 50 000 V

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C273.5:11 (R2025) – Installation of air source heat pumps and air conditioners

$

199

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA C239:02 (R2026) – Performance standard for dusk-to-dawn luminaires

$

128

BUY NOW

CSA C309:M90 (R2024)

CSA C309:M90 (R2024) – Performance Requirements for Glass-Lined Storage Tanks for Household Hot Water Service

CDN $125.00

Performance Requirements for Glass-Lined Storage Tanks for Household Hot Water Service

SKU: 2413733 Categories: ,

Description

Preface This is the second edition of CSA Standard CAN/CSA-C309, Performance Requirements for Glass-Lined Storage Tanks for Household Hot Water Service. This Standard covers electrically, gas-fired, and oil-heated storage tanks. It supersedes the first edition published in August 1977, shall be the standard. Dimensions have been converted to SI (metric) units, which values shall be standard. The yard-pound (Imperial) units given in parentheses are provided for information only. This standard was prepared by the Technical Committee on Electrical Storage-Tank Water Heaters under the jurisdiction of the Standards Steering Committee on the Performance of Electrical Products and was formally approved by these Committees. It has been approved as a National Standard of Canada by the Standards Council of Canada. Scope 1.1 This Standard applies to glass-lined storage tanks for household hot water service. Requirements are given for base metal, construction, glass lining, cathodic protection, inspection, and testing. 1.2 This Standard covers glass-lined storage tanks at the point of manufacture, having 610 mm (24 in) inside diameter and less, with a maximum working pressure of 1034 kPa (150 psi), and subject to maximum input limitations as follows: (a) electric – single element, 4500 W; (b) electric – double element, 4500 W upper, 4500 W lower, flip flop circuit (alternate operation); (c) oil-fired – 2.84 L/h (0.75 US gal/h) or less; and (d) gas-fired – less than 21 980 W (75 000 Btuh). 1.3 The values given in SI (metric) units are the standard. The values given in parentheses are for information only.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

28

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CSA Standard CAN/CSA-C309, Performance Requirements for Glass-Lined Storage Tanks for Household Hot Water Service. This Standard covers electrically, gas-fired, and oil-heated storage tanks. It supersedes the first edition published in August 1977, shall be the standard. Dimensions have been converted to SI (metric) units, which values shall be standard. The yard-pound (Imperial) units given in parentheses are provided for information only. This standard was prepared by the Technical Committee on Electrical Storage-Tank Water Heaters under the jurisdiction of the Standards Steering Committee on the Performance of Electrical Products and was formally approved by these Committees. It has been approved as a National Standard of Canada by the Standards Council of Canada. Scope 1.1 This Standard applies to glass-lined storage tanks for household hot water service. Requirements are given for base metal, construction, glass lining, cathodic protection, inspection, and testing. 1.2 This Standard covers glass-lined storage tanks at the point of manufacture, having 610 mm (24 in) inside diameter and less, with a maximum working pressure of 1034 kPa (150 psi), and subject to maximum input limitations as follows: (a) electric - single element, 4500 W; (b) electric - double element, 4500 W upper, 4500 W lower, flip flop circuit (alternate operation); (c) oil-fired - 2.84 L/h (0.75 US gal/h) or less; and (d) gas-fired - less than 21 980 W (75 000 Btuh). 1.3 The values given in SI (metric) units are the standard. The values given in parentheses are for information only.