Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C49.3:10 (R2023)

CSA C49.3:10 (R2023) – Aluminum 1350 wire, annealed and intermediate tempers, for electrical purposes

CDN $150.00

Aluminum 1350 wire, annealed and intermediate tempers, for electrical purposes

SKU: 2420520 Categories: ,

Description

Preface This is the second edition of CSA C49.3, Aluminum 1350 wire, annealed and intermediate tempers, for electrical purposes. It supersedes the previous edition, published in 1977 under the title Aluminum Alloy 1350 Round Wire, All Tempers, for Electrical Purposes. This Standard covers the electrical and mechanical characteristics of aluminum 1350 wire, annealed and intermediate tempers, for stranding into conductors or for use as solid single conductors. For aluminum 1350-H19 wire, reference should be made to CAN/CSA-C60889. This Standard was prepared by the Technical Committee on Overhead Electrical Conductors, under the jurisdiction of the Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard covers the electrical and mechanical characteristics of aluminum 1350 wire, in annealed and intermediate tempers, for stranding into conductors or for use as solid single conductors. 1.2 In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

17

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the second edition of CSA C49.3, Aluminum 1350 wire, annealed and intermediate tempers, for electrical purposes. It supersedes the previous edition, published in 1977 under the title Aluminum Alloy 1350 Round Wire, All Tempers, for Electrical Purposes. This Standard covers the electrical and mechanical characteristics of aluminum 1350 wire, annealed and intermediate tempers, for stranding into conductors or for use as solid single conductors. For aluminum 1350-H19 wire, reference should be made to CAN/CSA-C60889. This Standard was prepared by the Technical Committee on Overhead Electrical Conductors, under the jurisdiction of the Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard covers the electrical and mechanical characteristics of aluminum 1350 wire, in annealed and intermediate tempers, for stranding into conductors or for use as solid single conductors. 1.2 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.