
CSA C50052:24
CSA C50052:24 – High-voltage switchgear and controlgear — Gas-filled cast aluminium alloy enclosures (Adopted CENELEC EN 50052:2016, 2016-10, with Canadian deviations)
CDN $551.00
High-voltage switchgear and controlgear — Gas-filled cast aluminium alloy enclosures (Adopted CENELEC EN 50052:2016, 2016-10, with Canadian deviations)
Description
CSA Preface This is the second edition of CSA C50052, High-voltage switchgear and controlgear — Gas-filled cast aluminium alloy enclosures, which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50052 (2016-10). It supersedes the previous edition published in 1999 as CSA C50052 (adopted EN 50052:1986). For brevity, this Standard will be referred to as “CSA C50052” throughout. Funding in support of the consensus process of this Standard was provided by the following funders, whose assistance is acknowledged with thanks: Alectra Utilities, Electricity Canada (EC), EPCOR, Fortis Alberta, Fortis BC, Hydro One, Hydro-Québec, IFD Corporation, K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland & Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Switchgear and Controlgear, under the jurisdiction of the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This European Standard applies to cast aluminium alloy enclosures pressurized with dry air, inert gases, for example sulphur hexafluoride or nitrogen or a mixture of such gases, used in indoor or outdoor installations of high-voltage switchgear and controlgear above 1 kV, where the gas is used principally for its dielectric and/or arc-quenching properties with rated voltages – above 1 kV and up to and including 52 kV and with gas-filled enclosures with design pressure higher than 300 kPa relative pressure (gauge); – and with rated voltage above 52 kV. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: – Circuit-breakers – Switch-disconnectors – Disconnectors – Earthing switches – Current transformers – Voltage transformers – Surge arrestors – Busbars and connections – etc. The scope also covers enclosures of pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
41
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CSA C50052, High-voltage switchgear and controlgear — Gas-filled cast aluminium alloy enclosures, which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50052 (2016-10). It supersedes the previous edition published in 1999 as CSA C50052 (adopted EN 50052:1986). For brevity, this Standard will be referred to as "CSA C50052" throughout. Funding in support of the consensus process of this Standard was provided by the following funders, whose assistance is acknowledged with thanks: Alectra Utilities, Electricity Canada (EC), EPCOR, Fortis Alberta, Fortis BC, Hydro One, Hydro-Québec, IFD Corporation, K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland & Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Switchgear and Controlgear, under the jurisdiction of the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This European Standard applies to cast aluminium alloy enclosures pressurized with dry air, inert gases, for example sulphur hexafluoride or nitrogen or a mixture of such gases, used in indoor or outdoor installations of high-voltage switchgear and controlgear above 1 kV, where the gas is used principally for its dielectric and/or arc-quenching properties with rated voltages - above 1 kV and up to and including 52 kV and with gas-filled enclosures with design pressure higher than 300 kPa relative pressure (gauge); - and with rated voltage above 52 kV. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: - Circuit-breakers - Switch-disconnectors - Disconnectors - Earthing switches - Current transformers - Voltage transformers - Surge arrestors - Busbars and connections - etc. The scope also covers enclosures of pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart -

CSA SPE-3000:19 – Model code for the field evaluation of medical electrical equipment (MEE) and medical electrical systems (MES)
CDN $334.00 Add to cart -

CSA E60825-1:15 (R2025) – Safety of laser products — Part 1: Equipment classification and requirements (Adopted IEC 60825-1:2014, third edition, 2014-05, with Canadian deviations) | Sécurité des appareils à laser — Partie 1 : Classification des matériels et exigences (norme IEC 60825-1:2014 adoptée, troisième édition, 2014-05, avec exigences propres au Canada)
CDN $488.00 Add to cart -

CSA C22.3 NO. 5.1:93 (R2022) – Recommended practices for electrical protection – Electric contact between overhead supply and communication lines
CDN $149.00 Add to cart







