
CSA C50068:24
CSA C50068:24 – High-voltage switchgear and controlgear — Gas-filled wrought steel enclosures (Adopted CENELEC EN 50068:2018, 2018-11, with Canadian deviations)
CDN $559.00
High-voltage switchgear and controlgear — Gas-filled wrought steel enclosures (Adopted CENELEC EN 50068:2018, 2018-11, with Canadian deviations)
Description
CSA Preface This is the second edition of CSA C50068, High-voltage switchgear and controlgear — Gas-filled wrought steel enclosures, which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50068 (2018-11). It supersedes the previous edition published in 1999 as CSA C50068 (adopted EN 50068:1991). For brevity, this Standard will be referred to as “CSA C50068” throughout. Funding in support of the consensus process of this Standard was provided by the following funders, whose assistance is acknowledged with thanks: Alectra Utilities, Electricity Canada (EC), EPCOR, Fortis Alberta, FortisBC, Hydro One, Hydro-Québec, IFD Corporation, K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland & Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Switchgear and Controlgear, under the jurisdiction of the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This document applies to wrought steel enclosures and their welding. These enclosures are pressurized with dry air, inert gases, for example sulphur hexafluoride or nitrogen or a mixture of such gases, used in indoor and outdoor installations of high-voltage switchgear and controlgear with rated voltages above 1kV, where the gas is used principally for its dielectric and/or arc-quenching properties with rated voltages: — above 1 kV and up to and including 52 kV concerning gas-filled compartments with design pressure higher than 300 kPa relative pressure (gauge); — above 52 kV concerning all gas-filled compartments. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: — circuit-breakers; — switch-disconnectors; — disconnectors; — earthing switches; — current transformers; — voltage transformers; — surge arrestors; — busbars and connections; — etc. The scope also covers enclosures of pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
43
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CSA C50068, High-voltage switchgear and controlgear — Gas-filled wrought steel enclosures, which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50068 (2018-11). It supersedes the previous edition published in 1999 as CSA C50068 (adopted EN 50068:1991). For brevity, this Standard will be referred to as "CSA C50068" throughout. Funding in support of the consensus process of this Standard was provided by the following funders, whose assistance is acknowledged with thanks: Alectra Utilities, Electricity Canada (EC), EPCOR, Fortis Alberta, FortisBC, Hydro One, Hydro-Québec, IFD Corporation, K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland & Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Switchgear and Controlgear, under the jurisdiction of the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This document applies to wrought steel enclosures and their welding. These enclosures are pressurized with dry air, inert gases, for example sulphur hexafluoride or nitrogen or a mixture of such gases, used in indoor and outdoor installations of high-voltage switchgear and controlgear with rated voltages above 1kV, where the gas is used principally for its dielectric and/or arc-quenching properties with rated voltages: — above 1 kV and up to and including 52 kV concerning gas-filled compartments with design pressure higher than 300 kPa relative pressure (gauge); — above 52 kV concerning all gas-filled compartments. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: — circuit-breakers; — switch-disconnectors; — disconnectors; — earthing switches; — current transformers; — voltage transformers; — surge arrestors; — busbars and connections; — etc. The scope also covers enclosures of pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA TS-117:23 – National technical specification for terminology for the decentralized energy industry in Canada
CDN $79.00 Add to cart -

CSA E61951-2:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
CDN $527.00 Add to cart -

CAN/CSA-E60730-2-9:18 (R2023)/A2:24 – Amendment 2:2024 to CAN/CSA-E60730-2-9:18, Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted amendment 2:2020 to IEC 60730-2-9:2018)
CDN $19.00 Add to cart -

IEEE 844.1-2017/CSA C22.2 NO. 293.1:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—General, testing, marking, and documentation requirements
CDN $158.00 Add to cart







