Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C50089:99 (R2026)

CSA C50089:99 (R2026) – Cast resin partitions for metal-enclosed gas-filled high-voltage switchgear and controlgear (Adopted CENELEC 50089:1992, including amendment A1:1994, with Canadian deviations)

CDN $104.00

Cast resin partitions for metal-enclosed gas-filled high-voltage switchgear and controlgear (Adopted CENELEC 50089:1992, including amendment A1:1994, with Canadian deviations)

SKU: 2411601 Categories: ,

Description

CSA Preface This is the first edition of CSA Standard CAN/CSA-C50089, Cast resin partitions for metal-enclosed gas-filled high-voltage switchgear and controlgear, which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50 089 : 1 992 (1 992-05) including Amendment Al :1 994. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 2.1 Type of Equipment This standard applies to cast resin partitions pressurized with inert gases, eg, sulphur hexafluoride, carbon tetrafluoride, or a mixture of such gases, such as sulphur hexafluoride and nitrogen used in indoor and outdoor installations of high-voltage switchgear and controlgear, where the gas is used principally for its dielectric and/or arc-quenching properties, with rated voltages (a) 1 kV and up to and including 52 kV and with gas-filled compartments with design pressure greater than 3 bar (gauge); and (b) 72.5 kV and above. The partitions comprise pressurized barriers in electrical equipment not necessarily limited to the following examples: – Circuit breakers – Switch disconnectors – Disconnectors – Earthing switches – Current transformers – Voltage transformers  -Surge arresters – Busbars and connections – Cable and connections. This standard does not apply to high-voltage bushings (see HD 358 S3 (IEC 517)). 2.2 Quality assurance It is the intention of this standard that the switchgear manufacturer shall be responsible for achieving and maintaining a consistent and adequate quality of product. Sufficient examinations shall be made by the partition manufacturer to ensure that the materials, production and testing comply in all respects with the requirements of this standard. Inspections by the users’ inspectors shall not absolve the switchgear manufacturer from his responsibility to exercise such quality assurance procedures as to ensure that the requirements and intent of this standard are satisfied. NOTE. Reference should he made to the EN 2900() series of standards for quality assurance systems.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

18

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

CSA Preface This is the first edition of CSA Standard CAN/CSA-C50089, Cast resin partitions for metal-enclosed gas-filled high-voltage switchgear and controlgear, which is an adoption, with Canadian deviations, of the identically titled CENELEC (European Committee for Electrotechnical Standardization) Standard EN 50 089 : 1 992 (1 992-05) including Amendment Al :1 994. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 2.1 Type of Equipment This standard applies to cast resin partitions pressurized with inert gases, eg, sulphur hexafluoride, carbon tetrafluoride, or a mixture of such gases, such as sulphur hexafluoride and nitrogen used in indoor and outdoor installations of high-voltage switchgear and controlgear, where the gas is used principally for its dielectric and/or arc-quenching properties, with rated voltages (a) 1 kV and up to and including 52 kV and with gas-filled compartments with design pressure greater than 3 bar (gauge); and (b) 72.5 kV and above. The partitions comprise pressurized barriers in electrical equipment not necessarily limited to the following examples: - Circuit breakers - Switch disconnectors - Disconnectors - Earthing switches - Current transformers - Voltage transformers  -Surge arresters - Busbars and connections - Cable and connections. This standard does not apply to high-voltage bushings (see HD 358 S3 (IEC 517)). 2.2 Quality assurance It is the intention of this standard that the switchgear manufacturer shall be responsible for achieving and maintaining a consistent and adequate quality of product. Sufficient examinations shall be made by the partition manufacturer to ensure that the materials, production and testing comply in all respects with the requirements of this standard. Inspections by the users' inspectors shall not absolve the switchgear manufacturer from his responsibility to exercise such quality assurance procedures as to ensure that the requirements and intent of this standard are satisfied. NOTE. Reference should he made to the EN 2900() series of standards for quality assurance systems.