Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C50:14 (R2023)

CSA C50:14 (R2023) – Mineral insulating oil, electrical, for transformers and switches

CDN $189.00

Mineral insulating oil, electrical, for transformers and switches

SKU: 2423057 Categories: ,

Description

Preface This is the seventh edition of CSA C50, Mineral insulating oil electrical for transformers and switches. It supersedes the 2008 edition of the same title and the 1997, 1976, 1965, 1958, and 1938 editions, which were titled Insulating oil electrical for transformers and switches. The changes introduced in this edition are the following: a) Requirements for the detection of potentially corrosive sulphur have been added; b) Requirements for the detection of dibenzyldisulphide (DBDS) have been added; c) Requirements for the detection of metal passivators in oxidation inhibitors have been added; and d) Requirements concerning additives in oil have been added. It needs to be recognized that the tests specified in this Standard do not indicate the relative service lives of different oils. Purchasers should use these tests to determine the characteristics of oils that have been found by experience to be satisfactory and to detect any significant variations in the characteristics of further shipments of such oils. This Standard was prepared by the Technical Committee on Transformer and Switch Oils, under the jurisdiction of the Strategic Steering Committee on Electrical Engineering, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies the requirements for mineral oil of petroleum origin for use in transformers, oil circuit breakers, or other electrical equipment (excluding high-voltage cables) requiring a liquid insulating and cooling medium. 1.2 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised by not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

21

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the seventh edition of CSA C50, Mineral insulating oil electrical for transformers and switches. It supersedes the 2008 edition of the same title and the 1997, 1976, 1965, 1958, and 1938 editions, which were titled Insulating oil electrical for transformers and switches. The changes introduced in this edition are the following: a) Requirements for the detection of potentially corrosive sulphur have been added; b) Requirements for the detection of dibenzyldisulphide (DBDS) have been added; c) Requirements for the detection of metal passivators in oxidation inhibitors have been added; and d) Requirements concerning additives in oil have been added. It needs to be recognized that the tests specified in this Standard do not indicate the relative service lives of different oils. Purchasers should use these tests to determine the characteristics of oils that have been found by experience to be satisfactory and to detect any significant variations in the characteristics of further shipments of such oils. This Standard was prepared by the Technical Committee on Transformer and Switch Oils, under the jurisdiction of the Strategic Steering Committee on Electrical Engineering, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies the requirements for mineral oil of petroleum origin for use in transformers, oil circuit breakers, or other electrical equipment (excluding high-voltage cables) requiring a liquid insulating and cooling medium. 1.2 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised by not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.