Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C506:23

CSA C506:23 – Benchmark energy factor (BEF) for industrial air movement systems

CDN $315.00

Benchmark energy factor (BEF) for industrial air movement systems

SKU: 2430966 Categories: ,

Description

Preface This is the first edition of CSA C506, Benchmark energy factor (BEF) for industrial air movement systems. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of BC Hydro, Efficiency Manitoba, Electricity Canada, Fortis BC Electric, Hydro Québec, and Northwest Energy Efficiency Alliance (NEEA). This Standard was prepared by the Subcommittee on Benchmark Energy Factor for Industrial Fan system, under the jurisdiction of the Technical Committee on Energy Efficiency of Industrial Equipment and Systems and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard is intended for industrial air handling systems with the following characteristics: a) systems with energy consumption greater than 500 000 kWh per year; b) systems with air flow greater than 9.4 m 3 /s (20 000 cfm); c) air movement systems with a maximum energy output limit of 25 kJ/kg of air, which is equivalent to a maximum pressure ratio of 1.3 per stage; d) flow velocity of ≤100 m/s (≤20 000 fpm), which characterizes the flow as incompressible; e) any single parallel or series configured for air supply, air collection, exhaust, induced draft, or forced draft applications; and f) for material handling applications, using dilute-phase conveying, with air-to-solid loading ratio ≥2.0 by weight. 1.2 Exclusions This Standard is not intended to be used for air movement systems with the following characteristics: a) systems without partition, i.e., ceiling fans, crossflow fans, and air curtain units; b) systems with partition and free inlet and outlet, i.e., sidewall fans; c) multi-room building ventilation systems; d) systems that have a pressure ratio greater than 1.3; e) for material handling application using dense phase conveying with air-to-solid loading ratio <2.0 by weight; and f) applications with air temperature greater than 250 ᵒC. 1.3 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.4 Measurements The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

49

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of CSA C506, Benchmark energy factor (BEF) for industrial air movement systems. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of BC Hydro, Efficiency Manitoba, Electricity Canada, Fortis BC Electric, Hydro Québec, and Northwest Energy Efficiency Alliance (NEEA). This Standard was prepared by the Subcommittee on Benchmark Energy Factor for Industrial Fan system, under the jurisdiction of the Technical Committee on Energy Efficiency of Industrial Equipment and Systems and the Strategic Steering Committee on Performance, Energy Efficiency, and Renewables, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard is intended for industrial air handling systems with the following characteristics: a) systems with energy consumption greater than 500 000 kWh per year; b) systems with air flow greater than 9.4 m 3 /s (20 000 cfm); c) air movement systems with a maximum energy output limit of 25 kJ/kg of air, which is equivalent to a maximum pressure ratio of 1.3 per stage; d) flow velocity of ≤100 m/s (≤20 000 fpm), which characterizes the flow as incompressible; e) any single parallel or series configured for air supply, air collection, exhaust, induced draft, or forced draft applications; and f) for material handling applications, using dilute-phase conveying, with air-to-solid loading ratio ≥2.0 by weight. 1.2 Exclusions This Standard is not intended to be used for air movement systems with the following characteristics: a) systems without partition, i.e., ceiling fans, crossflow fans, and air curtain units; b) systems with partition and free inlet and outlet, i.e., sidewall fans; c) multi-room building ventilation systems; d) systems that have a pressure ratio greater than 1.3; e) for material handling application using dense phase conveying with air-to-solid loading ratio <2.0 by weight; and f) applications with air temperature greater than 250 ᵒC. 1.3 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.4 Measurements The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Previous Editions

Can’t find what you are looking for?

Please contact us at: