Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C653:18 (R2024)

CSA C653:18 (R2024) – Photometric performance of roadway and street lighting luminaires

CDN $284.00

Photometric performance of roadway and street lighting luminaires

SKU: 2426703 Categories: ,

Description

Preface This is the fifth edition of CSA C653, Photometric performance of roadway and street lighting luminaires . It supersedes the previous editions published in 2013, 2008, 1994, and 1992. This Standard establishes the minimum performance requirements for roadway and street lighting luminaires. The requirements of this Standard are in addition to those specified in Canadian Electrical Code, Part I; CSA C22.2 No. 250.0, Luminaires; and CAN/CSA-C22.2 NO. 250.13, Light emitting diodes (LEDs) equipment for lighting applications. The major change to this edition includes updating the maximum UPD levels. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. CSA acknowledges that the development of this Standard was made possible, in part, by the financial support of BC Hydro, the Canadian Electricity Association, Hydro-Québec, Manitoba Hydro, Natural Resources Canada, and the Ontario Ministry of Energy. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies photometric performance requirements for luminaires that are used for roadway and street lighting applications as a function of unit power density (UPD). 1.2 The following light sources are addressed in this Standard: a) clear HPS lamp b) clear metal halide lamp and c) LED. 1.3 This Standard is based on a) average luminance, luminance uniformity ratio, and veiling luminance ratio as defined in ANSI/IES RP-8; b) nominal input power in watts for HID sources; c) rated lamp lumens for HID sources; d) relative photometry for HID sources as per ANSI/IES LM-63 and IES LM-31 e) luminaire input power in watts and rated luminaire lumens for LED sources and does not include constant light output (CLO) applications; and f) absolute photometry for LED sources as per IES LM-79. 1.4 This Standard is not a design document, and is intended to establish luminaire photometric performance efficiency only, based upon typical roadway configuration. Tables 4, 5, and 6 are intended to be used to establish maximum UPD values for typical applications as per the parameters listed in Table 1. UPD values provided in this Standard are not intended for specification or application purposes. User specific road geometries could differ from the templates used in the creation of these Tables. Requirements of specific designs might necessitate different variations in distribution, lumen packages, and wattages. Users should review UPD as a measure of comparison across suppliers, within their own geometry, and should note that UPD levels will then vary from the Tables within this Standard. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.6 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

31

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the fifth edition of CSA C653, Photometric performance of roadway and street lighting luminaires . It supersedes the previous editions published in 2013, 2008, 1994, and 1992. This Standard establishes the minimum performance requirements for roadway and street lighting luminaires. The requirements of this Standard are in addition to those specified in Canadian Electrical Code, Part I; CSA C22.2 No. 250.0, Luminaires; and CAN/CSA-C22.2 NO. 250.13, Light emitting diodes (LEDs) equipment for lighting applications. The major change to this edition includes updating the maximum UPD levels. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. CSA acknowledges that the development of this Standard was made possible, in part, by the financial support of BC Hydro, the Canadian Electricity Association, Hydro-Québec, Manitoba Hydro, Natural Resources Canada, and the Ontario Ministry of Energy. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies photometric performance requirements for luminaires that are used for roadway and street lighting applications as a function of unit power density (UPD). 1.2 The following light sources are addressed in this Standard: a) clear HPS lamp b) clear metal halide lamp and c) LED. 1.3 This Standard is based on a) average luminance, luminance uniformity ratio, and veiling luminance ratio as defined in ANSI/IES RP-8; b) nominal input power in watts for HID sources; c) rated lamp lumens for HID sources; d) relative photometry for HID sources as per ANSI/IES LM-63 and IES LM-31 e) luminaire input power in watts and rated luminaire lumens for LED sources and does not include constant light output (CLO) applications; and f) absolute photometry for LED sources as per IES LM-79. 1.4 This Standard is not a design document, and is intended to establish luminaire photometric performance efficiency only, based upon typical roadway configuration. Tables 4, 5, and 6 are intended to be used to establish maximum UPD values for typical applications as per the parameters listed in Table 1. UPD values provided in this Standard are not intended for specification or application purposes. User specific road geometries could differ from the templates used in the creation of these Tables. Requirements of specific designs might necessitate different variations in distribution, lumen packages, and wattages. Users should review UPD as a measure of comparison across suppliers, within their own geometry, and should note that UPD levels will then vary from the Tables within this Standard. 1.5 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.6 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Previous Editions

Can’t find what you are looking for?

Please contact us at: