
CSA C68.8:11 (R2025)
CSA C68.8:11 (R2025) – Overhead aluminum secondary and service-entrance cables and conductors for electrical distribution utilities
CDN $236.00
Overhead aluminum secondary and service-entrance cables and conductors for electrical distribution utilities
Description
Preface This is the first edition of CSA C68.8, Overhead aluminum secondary and service-entrance cables and conductors for electrical distribution utilities. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for overhead secondary and service-entrance cables and conductors intended primarily for operation by electrical utilities. Note: The operation of cables and conductors complying with this Standard by other than an electrical utility can be subject to additional requirements by an authority having jurisdiction. 1.2 The cables and conductors covered by this Standard are intended for overhead installation and for operation at normal maximum conductor temperatures of 75 °C and 90 °C. Provision is made for assembly of multiple conductors. Single 600 V insulated conductors are intended for field-spun applications. 1.3 In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
18
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the first edition of CSA C68.8, Overhead aluminum secondary and service-entrance cables and conductors for electrical distribution utilities. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for overhead secondary and service-entrance cables and conductors intended primarily for operation by electrical utilities. Note: The operation of cables and conductors complying with this Standard by other than an electrical utility can be subject to additional requirements by an authority having jurisdiction. 1.2 The cables and conductors covered by this Standard are intended for overhead installation and for operation at normal maximum conductor temperatures of 75 °C and 90 °C. Provision is made for assembly of multiple conductors. Single 600 V insulated conductors are intended for field-spun applications. 1.3 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-E61558-1:12 (R2022) – Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues – Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada)
CDN $630.00 Add to cart -

CSA G164:26 – Galvanizing of irregularly shaped articles
CDN $142.00 Add to cart -

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart -

CSA E61959:14 (R2024) – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Mechanical tests for sealed portable secondary cells and batteries (Adopted IEC 61959:2004, first edition, 2004-01, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide – Essais mécaniques pour accumulateurs portables étanches (norme CEI 61959:2004 adoptée, première édition, 2004-01, avec exigences propres au Canada)
CDN $56.00 Add to cart







