CSA C9:17 (R2022)
CSA C9:17 (R2022) – Dry-type transformers
CDN $189.00
Dry-type transformers
Description
Preface This is the fifth edition of CSA C9, Dry-type transformers. It supersedes the previous editions published in 2002, 1981, 1977, and 1966. Changes in this edition include the following: a) updates to insulation voltage classes and dielectric tests; b) updates to Annex D (Comparison of enclosures for indoor and outdoor non-hazardous locations); and c) alignment of average audible sound level with current industry practices. This Standard was prepared by the Technical Committee on Dry-Type Transformers, under the jurisdiction of the Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. Scope 1.1 This Standard applies to single phase and polyphase dry-type transformers, including those with cast or resin encapsulated coils, that are within the limits of the electrical ratings specified in Clauses 7.2 and 7.3, and that are intended for use in accordance with the service conditions for dry-type transformers specified in Annexes A and B. Notes: 1) For information on the loading of dry-type transformers, see IEEE C57.96. 2) For additional requirements for dry-type transformers in accordance with the Canadian Electrical Code, Part II, see CSA C22.2 No. 47. 1.2 This Standard deals with the standardization of voltage ratings, kVA capacities, other electrical features, certain mechanical features, and test procedures. 1.3 This Standard does not apply to transformers designed solely for test purposes, rectifier transformers, welding transformers, furnace transformers, instrument transformers, motor-starting autotransformers, or any other special purpose transformers. 1.4 In this Standard, the word “transformer” refers to a dry-type transformer, unless otherwise specifically stated. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
54
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the fifth edition of CSA C9, Dry-type transformers. It supersedes the previous editions published in 2002, 1981, 1977, and 1966. Changes in this edition include the following: a) updates to insulation voltage classes and dielectric tests; b) updates to Annex D (Comparison of enclosures for indoor and outdoor non-hazardous locations); and c) alignment of average audible sound level with current industry practices. This Standard was prepared by the Technical Committee on Dry-Type Transformers, under the jurisdiction of the Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. Scope 1.1 This Standard applies to single phase and polyphase dry-type transformers, including those with cast or resin encapsulated coils, that are within the limits of the electrical ratings specified in Clauses 7.2 and 7.3, and that are intended for use in accordance with the service conditions for dry-type transformers specified in Annexes A and B. Notes: 1) For information on the loading of dry-type transformers, see IEEE C57.96. 2) For additional requirements for dry-type transformers in accordance with the Canadian Electrical Code, Part II, see CSA C22.2 No. 47. 1.2 This Standard deals with the standardization of voltage ratings, kVA capacities, other electrical features, certain mechanical features, and test procedures. 1.3 This Standard does not apply to transformers designed solely for test purposes, rectifier transformers, welding transformers, furnace transformers, instrument transformers, motor-starting autotransformers, or any other special purpose transformers. 1.4 In this Standard, the word "transformer" refers to a dry-type transformer, unless otherwise specifically stated. 1.5 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA SPE-1000:25 – Model Code for the field evaluation of electrical equipment
CDN $378.00 Add to cart -

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart -

CAN/CSA-E60730-2-9:18 (R2023) – Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted IEC 60730-2-9:2018, edition 4:2015 consolidated with amendment 1:2018, with Canadian deviations)
CDN $944.00 Add to cart -

CSA E62660-1:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 1: Performance testing (Adopted IEC 62660-1:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 1 : Essais de performance (norme IEC 62660-1:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $436.00 Add to cart