CSA E60730-2-12:19 (R2024)
CSA E60730-2-12:19 (R2024) – Automatic electrical controls – Part 2-12: Particular requirements for electrically operated door locks (Adopted IEC 60730-2-12:2015, third edition, 2015-04, with Canadian deviations)
CDN $280.00
Automatic electrical controls – Part 2-12: Particular requirements for electrically operated door locks (Adopted IEC 60730-2-12:2015, third edition, 2015-04, with Canadian deviations)
Description
CSA Preface This is the second edition of CSA E60730-2-12, Automatic electrical controls — Part 2-12: Particular requirements for electrically operated door locks , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60730-2-12 (third edition, 2015-04). It supersedes the previous edition published in 1994 as CAN/CSA-E730-2-12 (adopted IEC 730-2-12:1993). At the time of publication, IEC 60730-2-12:2015 is available from IEC in English only. CSA Group will publish the French version when it becomes available from IEC. For brevity, this Standard will be referred to as “CSA E60730-2-12” throughout. This Standard is intended to be used in conjunction with CAN/CSA-E60730-1:15, Automatic electrical controls — Part 1: General requirements (adopted IEC 60730-1:2013, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on International Standards, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and normative references This clause of Part 1 is applicable except as follows: 1.1 Scope Replacement: This part of IEC 60730 applies to electrically operated door locks for use in, on or in association with equipment, including equipment for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. NOTE 1 Throughout this standard, the word “equipment” includes “appliance” and “control system”. This standard also applies to electrically operated door locks for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This standard does not apply to electrically operated door locks intended exclusively for industrial process applications unless explicitly mentioned in the equipment standard. This standard does not apply to electrically operated door locks intended for security access applications. NOTE 2 Standards that cover these applications are under IEC Technical Committee 79. 1.1.1 Replacement: This standard applies to the inherent safety, to the operating values, operating sequences where such are associated with equipment protection, and to the testing of door locks used in, or in association with equipment. This standard is also applicable to door locks for appliances within the scope of IEC 60335-1. NOTE Throughout this standard, the word “door” means “door, cover or lid”. The words “door lock” mean “electrically operated door lock”. This standard is also applicable to individual door locks utilized as part of a control system or door locks which are mechanically integral with multi-functional controls having non-electrical outputs or employing motors. Door locks for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. This standard is also applicable to the functional safety of low complexity safety related systems and controls employing door locks as the actuating element. 1.1.2 Replacement: This standard applies to door locks with electrical circuits and control circuits which are, for example, operated by bimetals, magnet coils, memory metals, pressure elements, temperature-sensitive expansion elements or electronic elements. 1.1.3 Not applicable. 1.1.4 Replacement: This standard applies to manual controls when such are electrically and/or mechanically integral with door locks. NOTE Requirements for manual switches not forming part of a door lock are contained in IEC 61058-1. 1.1.5 Replacement: This standard applies to a.c. or d.c. powered door locks with a rated voltage not exceeding 690 V a.c. or 600 V d.c. 1.1.6 Replacement: This standard does not take into account the response value of an automatic action of a door lock, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer shall apply. 1.1.7 Replacement: This standard applies also to door locks incorporating electronic devices, requirements for which are contained in Annex H and door locks using thermistors, requirements for which are contained in Annex J.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
37
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CSA E60730-2-12, Automatic electrical controls — Part 2-12: Particular requirements for electrically operated door locks , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60730-2-12 (third edition, 2015-04). It supersedes the previous edition published in 1994 as CAN/CSA-E730-2-12 (adopted IEC 730-2-12:1993). At the time of publication, IEC 60730-2-12:2015 is available from IEC in English only. CSA Group will publish the French version when it becomes available from IEC. For brevity, this Standard will be referred to as "CSA E60730-2-12" throughout. This Standard is intended to be used in conjunction with CAN/CSA-E60730-1:15, Automatic electrical controls — Part 1: General requirements (adopted IEC 60730-1:2013, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on International Standards, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and normative references This clause of Part 1 is applicable except as follows: 1.1 Scope Replacement: This part of IEC 60730 applies to electrically operated door locks for use in, on or in association with equipment, including equipment for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. NOTE 1 Throughout this standard, the word "equipment" includes "appliance" and "control system". This standard also applies to electrically operated door locks for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This standard does not apply to electrically operated door locks intended exclusively for industrial process applications unless explicitly mentioned in the equipment standard. This standard does not apply to electrically operated door locks intended for security access applications. NOTE 2 Standards that cover these applications are under IEC Technical Committee 79. 1.1.1 Replacement: This standard applies to the inherent safety, to the operating values, operating sequences where such are associated with equipment protection, and to the testing of door locks used in, or in association with equipment. This standard is also applicable to door locks for appliances within the scope of IEC 60335-1. NOTE Throughout this standard, the word "door" means "door, cover or lid". The words "door lock" mean "electrically operated door lock". This standard is also applicable to individual door locks utilized as part of a control system or door locks which are mechanically integral with multi-functional controls having non-electrical outputs or employing motors. Door locks for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. This standard is also applicable to the functional safety of low complexity safety related systems and controls employing door locks as the actuating element. 1.1.2 Replacement: This standard applies to door locks with electrical circuits and control circuits which are, for example, operated by bimetals, magnet coils, memory metals, pressure elements, temperature-sensitive expansion elements or electronic elements. 1.1.3 Not applicable. 1.1.4 Replacement: This standard applies to manual controls when such are electrically and/or mechanically integral with door locks. NOTE Requirements for manual switches not forming part of a door lock are contained in IEC 61058-1. 1.1.5 Replacement: This standard applies to a.c. or d.c. powered door locks with a rated voltage not exceeding 690 V a.c. or 600 V d.c. 1.1.6 Replacement: This standard does not take into account the response value of an automatic action of a door lock, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer shall apply. 1.1.7 Replacement: This standard applies also to door locks incorporating electronic devices, requirements for which are contained in Annex H and door locks using thermistors, requirements for which are contained in Annex J.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-E61965:04 (R2023) – Mechanical safety of cathode ray tubes (Adopted IEC 61965:2003, second edition, 2003-07, with Canadian deviations)
CDN $356.00 Add to cart -

IEEE 844.3-2019/CSA C22.2 NO. 293.3:19 (R2024) – Impedance heating of pipelines and equipment—General, testing, marking, and documentation requirements
CDN $174.00 Add to cart -

CSA SPE-1000:25 – Model Code for the field evaluation of electrical equipment
CDN $378.00 Add to cart -

CSA E61951-2:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
CDN $527.00 Add to cart