
CSA E61951-2:21 (R2026)
CSA E61951-2:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
CDN $527.00
Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
Description
CSA Preface This is the second edition of CSA E61951-2, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61951-2 (fourth edition, 2017-03). It supersedes the previous edition, published in 2014 as CAN/CSA-E61951-2 (adopted IEC 61951-2:2011). For brevity, this Standard will be referred to as “CSA E61951-2” throughout. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Subcommittee on Batteries and Batteries Systems, under the jurisdiction of the CSA Technical Committee on General Requirements, CE Code, Part II and the CSA Strategic Steering Committee on Requirements for Electrical Safety. It has been formally approved by the CSA Technical Committee on International Standards, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 61951 specifies marking, designation, dimensions, tests and requirements for secondary sealed nickel-metal hydride small prismatic, cylindrical and button cells and batteries, suitable for use in any orientation, for portable applications. ——————————————————————————————————————————– Préface CSA Ce document constitue la deuxième édition de CSA E61951-2, Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61951-2 (quatrième édition, 2017-03), qui porte le même titre. Il remplace l’édition antérieure publiée en 2014 qui portait la désignation CAN/CSA-E61951-2 (norme IEC 61951-2:2011 adoptée). Par souci de brièveté, tout au long de ce document, il sera appelé « CSA E61951-2 ». Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption au Canada par le Sous-comité CSA sur les batteries et les systèmes de batteries, sous l’autorité du Comité technique CSA sur les exigences générales, Code CÉ, Deuxième partie et du Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité. Cette norme a été officiellement approuvée par le Comité technique CSA sur les normes internationales, sous l’autorité du Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application La présente partie de l’IEC 61951 spécifie le marquage, la désignation, les dimensions, les essais et les exigences applicables aux éléments et batteries d’accumulateurs parallélépipédiques, cylindriques et boutons, étanches, au nickel-métal hydrure, pouvant être utilisés dans toutes les orientations, pour applications portables.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
117
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CSA E61951-2, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61951-2 (fourth edition, 2017-03). It supersedes the previous edition, published in 2014 as CAN/CSA-E61951-2 (adopted IEC 61951-2:2011). For brevity, this Standard will be referred to as “CSA E61951-2” throughout. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Subcommittee on Batteries and Batteries Systems, under the jurisdiction of the CSA Technical Committee on General Requirements, CE Code, Part II and the CSA Strategic Steering Committee on Requirements for Electrical Safety. It has been formally approved by the CSA Technical Committee on International Standards, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 61951 specifies marking, designation, dimensions, tests and requirements for secondary sealed nickel-metal hydride small prismatic, cylindrical and button cells and batteries, suitable for use in any orientation, for portable applications. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de CSA E61951-2, Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61951-2 (quatrième édition, 2017-03), qui porte le même titre. Il remplace l'édition antérieure publiée en 2014 qui portait la désignation CAN/CSA-E61951-2 (norme IEC 61951-2:2011 adoptée). Par souci de brièveté, tout au long de ce document, il sera appelé « CSA E61951-2 ». Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption au Canada par le Sous-comité CSA sur les batteries et les systèmes de batteries, sous l’autorité du Comité technique CSA sur les exigences générales, Code CÉ, Deuxième partie et du Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité. Cette norme a été officiellement approuvée par le Comité technique CSA sur les normes internationales, sous l’autorité du Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d'application La présente partie de l'IEC 61951 spécifie le marquage, la désignation, les dimensions, les essais et les exigences applicables aux éléments et batteries d’accumulateurs parallélépipédiques, cylindriques et boutons, étanches, au nickel-métal hydrure, pouvant être utilisés dans toutes les orientations, pour applications portables.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

IEEE 844.4-2019/CSA C293.4:19 (R2024) – Impedance heating of pipelines and equipment—Application guide for design, installation, testing, commissioning, and maintenance
CDN $174.00 Add to cart -

CAN/CSA-E61558-1:12 (R2022) – Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues – Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada)
CDN $630.00 Add to cart -

CSA TS-117:23 – National technical specification for terminology for the decentralized energy industry in Canada
CDN $79.00 Add to cart -

IEEE 844.1-2017/CSA C22.2 NO. 293.1:17 (R2022) – Skin effect trace heating of pipelines, vessels, equipment, and structures—General, testing, marking, and documentation requirements
CDN $158.00 Add to cart







