Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA S448.1:10 (R2025)

CSA S448.1:10 (R2025) – Repair of reinforced concrete in buildings and parking structures

CDN $295.00

Repair of reinforced concrete in buildings and parking structures

SKU: 2420671 Categories: ,

Description

This is the second edition of CSA S448.1, Repair of reinforced concrete in buildings and parking structures . It replaces the previous edition, published in 1993. This Standard specifies minimum requirements for the investigation, design, and execution of repair work needed to restore reinforced concrete structural components of buildings to a safe and serviceable state. It provides a framework for the design of repair projects and covers repair techniques and materials in a general way; engineers are responsible for selecting appropriate procedures and materials to obtain the desired performance. This Standard covers the repair of regular (i.e., not pre-stressed or post-tensioned) reinforced concrete structural elements in buildings and parking structures. This Standard addresses the need to ensure the structural integrity and safety of a building during the repair period and the need for the engineer to establish follow-up maintenance and monitoring programs for implementation by the building owner. This Standard reflects the current state of knowledge regarding concrete repair technology. It recognizes that, in the design of a repair project, the engineer works closely with the owner to determine the owner’s requirements for service life following repair and his or her commitment to regular maintenance of the structure. Scope 1.1 This Standard specifies requirements for the repair of reinforced structural concrete components of buildings and parking structures. 1.2 This Standard does not cover repairs to (a) pre-stressed, including post-tensioned, components and structures; or (b) non-structural slabs-on-grade. 1.3 This Standard does not cover repairs to (a) docks and wharves; (b) highway bridges; (c) bins, tanks, and silos; or (d) treatment plants. 1.4 This Standard is generally limited to materials and procedures pertaining to repairs that are accepted as industry standard and based on sound engineering practice. This Standard does not prohibit the use of innovative procedures and materials provided that (a) such procedures are carried out by persons qualified in the specific methods applied; (b) an acceptable level of safety and performance is provided when one of the following methods is used: (i) analysis based on generally established theory; (ii) evaluation of a full-scale structure or a prototype; or (iii) studies of model analogues; and (c) such methods are acceptable to the owner. 1.5 This Standard specifies requirements for the preparation of recommendations for installation of appropriate protection materials or systems and for post-repair maintenance schedules in order to provide protection to repaired structures and components. 1.6 In CSA standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

56

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This is the second edition of CSA S448.1, Repair of reinforced concrete in buildings and parking structures . It replaces the previous edition, published in 1993. This Standard specifies minimum requirements for the investigation, design, and execution of repair work needed to restore reinforced concrete structural components of buildings to a safe and serviceable state. It provides a framework for the design of repair projects and covers repair techniques and materials in a general way; engineers are responsible for selecting appropriate procedures and materials to obtain the desired performance. This Standard covers the repair of regular (i.e., not pre-stressed or post-tensioned) reinforced concrete structural elements in buildings and parking structures. This Standard addresses the need to ensure the structural integrity and safety of a building during the repair period and the need for the engineer to establish follow-up maintenance and monitoring programs for implementation by the building owner. This Standard reflects the current state of knowledge regarding concrete repair technology. It recognizes that, in the design of a repair project, the engineer works closely with the owner to determine the owner’s requirements for service life following repair and his or her commitment to regular maintenance of the structure. Scope 1.1 This Standard specifies requirements for the repair of reinforced structural concrete components of buildings and parking structures. 1.2 This Standard does not cover repairs to (a) pre-stressed, including post-tensioned, components and structures; or (b) non-structural slabs-on-grade. 1.3 This Standard does not cover repairs to (a) docks and wharves; (b) highway bridges; (c) bins, tanks, and silos; or (d) treatment plants. 1.4 This Standard is generally limited to materials and procedures pertaining to repairs that are accepted as industry standard and based on sound engineering practice. This Standard does not prohibit the use of innovative procedures and materials provided that (a) such procedures are carried out by persons qualified in the specific methods applied; (b) an acceptable level of safety and performance is provided when one of the following methods is used: (i) analysis based on generally established theory; (ii) evaluation of a full-scale structure or a prototype; or (iii) studies of model analogues; and (c) such methods are acceptable to the owner. 1.5 This Standard specifies requirements for the preparation of recommendations for installation of appropriate protection materials or systems and for post-repair maintenance schedules in order to provide protection to repaired structures and components. 1.6 In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.