Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA S850:25

CSA S850:25 – Design and assessment of buildings subjected to blast loads

CDN $315.00

Design and assessment of buildings subjected to blast loads

SKU: 2431959 Categories: ,

Description

Preface This is the third edition of CSA S850, Design and assessment of buildings subjected to blast loads . It supersedes the previous editions published in 2023 and 2012. A significant update to this edition is the commentary in Annex A that provides explanatory material, as well as useful supplementary information, and should be read in conjunction with this Standard. This Standard is intended for use in the design of new buildings and assessment of existing buildings to resist defined blast threats. While building security, within the context of building protection against blast threats, is beyond the scope of this Standard, it is an essential aspect to evaluating or modifying the design threat and thus must be well understood by the designer. Although not specifically identified, users should be aware that the authority having jurisdiction might have additional approval requirements, which are outside of the scope of this Standard. CSA Group acknowledges that the development of this Standard was supported by Global Affairs Canada with financial support from Defence Research and Development Canada’s Centre for Security Science. This Standard was prepared by the Technical Committee on Blast-Resistant Buildings, under the jurisdiction of the Strategic Steering Committee on Construction and Civil Infrastructure, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard provides criteria for the analysis and design of new buildings and assessment of existing buildings to resist blast loading. Notes: 1) The main objective of this Standard is to reduce human casualties and damage to assets due to an air blast. 2) It should be recognized that the extent and severity of an explosion and resulting damage cannot be predicted with certainty. 3) The performance of the building and the safety of the occupants are functions of the selected LOP and the DBT. 4) Users should ensure they are familiar with applicable legislation. Where this Standard conflicts with applicable legislation, it is assumed the legislation applies. 1.2 Materials considered This Standard provides design criteria for concrete, FRP, masonry, steel, and wood. This does not preclude the use of other materials (see Clause 9.1). Note: FRP design provisions apply to retrofit only. 1.3 Items not addressed 1.3.1 This Standard does not address risk assessment or apply to biological, chemical, cratering, EMP, ground shock, fragmentation loads, induced fire, penetration, perimeter security, radiation, or thermal effects of explosions. Note: Although other effects of explosion such as fragmentation are important considerations, special design requirements have not been provided in this Standard. 1.3.2 This Standard does not define a DBT. A DBT is building- and project-specific, and it should be specified by the building owner and/or the AHJ. 1.4 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 Units of measurement Equations appearing in this Standard are compatible with the following units: a) area: mm2 (square millimetres); b) force: N (newtons); c) length: mm (millimetres); d) mass: kg; e) moment: N•mm (newton millimetres); and f) stress: MPa (megapascals).

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

176

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the third edition of CSA S850, Design and assessment of buildings subjected to blast loads . It supersedes the previous editions published in 2023 and 2012. A significant update to this edition is the commentary in Annex A that provides explanatory material, as well as useful supplementary information, and should be read in conjunction with this Standard. This Standard is intended for use in the design of new buildings and assessment of existing buildings to resist defined blast threats. While building security, within the context of building protection against blast threats, is beyond the scope of this Standard, it is an essential aspect to evaluating or modifying the design threat and thus must be well understood by the designer. Although not specifically identified, users should be aware that the authority having jurisdiction might have additional approval requirements, which are outside of the scope of this Standard. CSA Group acknowledges that the development of this Standard was supported by Global Affairs Canada with financial support from Defence Research and Development Canada’s Centre for Security Science. This Standard was prepared by the Technical Committee on Blast-Resistant Buildings, under the jurisdiction of the Strategic Steering Committee on Construction and Civil Infrastructure, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This Standard provides criteria for the analysis and design of new buildings and assessment of existing buildings to resist blast loading. Notes: 1) The main objective of this Standard is to reduce human casualties and damage to assets due to an air blast. 2) It should be recognized that the extent and severity of an explosion and resulting damage cannot be predicted with certainty. 3) The performance of the building and the safety of the occupants are functions of the selected LOP and the DBT. 4) Users should ensure they are familiar with applicable legislation. Where this Standard conflicts with applicable legislation, it is assumed the legislation applies. 1.2 Materials considered This Standard provides design criteria for concrete, FRP, masonry, steel, and wood. This does not preclude the use of other materials (see Clause 9.1). Note: FRP design provisions apply to retrofit only. 1.3 Items not addressed 1.3.1 This Standard does not address risk assessment or apply to biological, chemical, cratering, EMP, ground shock, fragmentation loads, induced fire, penetration, perimeter security, radiation, or thermal effects of explosions. Note: Although other effects of explosion such as fragmentation are important considerations, special design requirements have not been provided in this Standard. 1.3.2 This Standard does not define a DBT. A DBT is building- and project-specific, and it should be specified by the building owner and/or the AHJ. 1.4 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 Units of measurement Equations appearing in this Standard are compatible with the following units: a) area: mm2 (square millimetres); b) force: N (newtons); c) length: mm (millimetres); d) mass: kg; e) moment: N•mm (newton millimetres); and f) stress: MPa (megapascals).

Previous Editions

Can’t find what you are looking for?

Please contact us at: