ISO 13196:2026
ISO 13196:2026 Soil quality — Screening soils for selected elements by energy-dispersive X-ray fluorescence spectrometry using a handheld or portable instrument
CDN $251.00
This publication was last reviewed and confirmed in 2026.
Soil quality — Screening soils for selected elements by energy-dispersive X-ray fluorescence spectrometry using a handheld or portable instrument
Description
This document specifies the procedure for screening soils for selected elements using handheld or portable equipment for energy dispersive X-ray fluorescence spectrometry (ED-XRF). It covers the application of this screening method to obtain qualitative or semi-quantitative data to assist decisions on a sampling strategy for detailed assessment of soil quality employing laboratory analytical chemical methods.
NOTE 1 Screening methods generally provide qualitative or semi-quantitative concentration values that are indicative of concentration values, although occasionally they can give quantitative results under specific or limited conditions.
NOTE 2 The greater the effort applied to the pretreatment of soil samples, the better the analytical results that can be expected (see e.g. Reference [19]).
This document does not explicitly specify elements for which it is applicable, since the applicability depends on the performance of the apparatus and the objective of the screening. The elements which can be determined are limited by the performance of the instrument used, the concentrations of particular elements present in the soil, and the requirements of the investigation in terms of the minimum concentrations of concern (e.g. guideline value).
NOTE 3 The XRF measurements of As, Cd, Co, Cr, Cu, Hg, Mo, Ni, Pb, Sb, Sn, V and Zn were validated as described in Annex A.
NOTE 4 Annex B provides examples of when screening with a handheld ED-XRF spectrometer and a portable ED-XRF spectrometer can be useful.
This document does not provide guidance on how to use the equipment to provide quantitative data for use in detailed site assessments. This document does not cover how the results of multiple determinations are synthesized to address the objectives of an ED-XRF determination.
Edition
2
Published Date
2026-06-19
Status
PUBLISHED
Pages
22
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies the procedure for screening soils for selected elements using handheld or portable equipment for energy dispersive X-ray fluorescence spectrometry (ED-XRF). It covers the application of this screening method to obtain qualitative or semi-quantitative data to assist decisions on a sampling strategy for detailed assessment of soil quality employing laboratory analytical chemical methods.
NOTE 1 Screening methods generally provide qualitative or semi-quantitative concentration values that are indicative of concentration values, although occasionally they can give quantitative results under specific or limited conditions.
NOTE 2 The greater the effort applied to the pretreatment of soil samples, the better the analytical results that can be expected (see e.g. Reference [19]).
This document does not explicitly specify elements for which it is applicable, since the applicability depends on the performance of the apparatus and the objective of the screening. The elements which can be determined are limited by the performance of the instrument used, the concentrations of particular elements present in the soil, and the requirements of the investigation in terms of the minimum concentrations of concern (e.g. guideline value).
NOTE 3 The XRF measurements of As, Cd, Co, Cr, Cu, Hg, Mo, Ni, Pb, Sb, Sn, V and Zn were validated as described in Annex A.
NOTE 4 Annex B provides examples of when screening with a handheld ED-XRF spectrometer and a portable ED-XRF spectrometer can be useful.
This document does not provide guidance on how to use the equipment to provide quantitative data for use in detailed site assessments. This document does not cover how the results of multiple determinations are synthesized to address the objectives of an ED-XRF determination.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 16729:2013 Soil quality – Digestion of nitric acid soluble fractions of elements
CDN $124.00 Add to cart -

ISO 13536:2024 Soil quality – Determination of the potential cation exchange capacity and exchangeable cations using barium chloride solution buffered at pH = 8,1
CDN $124.00 Add to cart -

ISO 17184:2014 Soil quality – Determination of carbon and nitrogen by near-infrared spectrometry (NIRS)
CDN $124.00 Add to cart -

ISO 18227:2014 Soil quality – Determination of elemental composition by X-ray fluorescence
CDN $336.00 Add to cart