
ISO 13548:2025
ISO 13548:2025 Copper and zinc sulfide concentrates — Determination of fluorine content by sodium hydroxide fusion and fluoride ion selective electrode detection
CDN $186.00
This publication was last reviewed and confirmed in 2025.
Copper and zinc sulfide concentrates — Determination of fluorine content by sodium hydroxide fusion and fluoride ion selective electrode detection
Description
This document specifies a procedure for the determination of fluorine in copper and zinc sulfide concentrates by sodium hydroxide fusion and fluoride ion selective electrode (FISE) detection. Fluoride ions are leached from the sodium hydroxide fusion and presented to the FISE. Potential interfering ions are masked by the use of a complexing agent and control of solution pH. If the aluminium content in the concentrate is up to a mass fraction of 4,5 %, there is no effect of aluminium in this method. However, if the aluminium content in the concentrate exceeds a mass fraction of 4,5 %, there is a possibility that it can affect the analytical results.
The method is applicable to fluorine in the following ranges:
— copper concentrates: mass fraction of 0,008 % to 0,3 %;
— zinc concentrates: mass fraction of 0,005 % to 0,1 %.
The results of the trueness test can be found in Annex C.
Edition
1
Published Date
2026-06-18
Status
PUBLISHED
Pages
18
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies a procedure for the determination of fluorine in copper and zinc sulfide concentrates by sodium hydroxide fusion and fluoride ion selective electrode (FISE) detection. Fluoride ions are leached from the sodium hydroxide fusion and presented to the FISE. Potential interfering ions are masked by the use of a complexing agent and control of solution pH. If the aluminium content in the concentrate is up to a mass fraction of 4,5 %, there is no effect of aluminium in this method. However, if the aluminium content in the concentrate exceeds a mass fraction of 4,5 %, there is a possibility that it can affect the analytical results.
The method is applicable to fluorine in the following ranges:
— copper concentrates: mass fraction of 0,008 % to 0,3 %;
— zinc concentrates: mass fraction of 0,005 % to 0,1 %.
The results of the trueness test can be found in Annex C.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 5078:2025 Management of terminology resources – Terminology extraction
CDN $251.00 Add to cart -

ISO 80004:2011 Nanotechnologies – Vocabulary – Part 5: Nano/bio interface
CDN $82.00 Add to cart -

ISO 10110:2019 Optics and photonics – Preparation of drawings for optical elements and systems – Part 1: General
CDN $336.00 Add to cart -

ISO 1176:1990 Road vehicles – Masses – Vocabulary and codes
CDN $124.00 Add to cart







