
ISO 18090-1:2026
ISO 18090-1:2026 Radiological protection — Characteristics of reference pulsed radiation — Part 1: Photon radiation
CDN $186.00
This publication was last reviewed and confirmed in 2026.
Radiological protection — Characteristics of reference pulsed radiation — Part 1: Photon radiation
Description
This document is directly applicable to pulsed X-radiation with pulse duration of 0,1 ms up to 10 s. This range covers the whole range used in medical diagnostics at the time of publication. Some specifications can also be applicable for much shorter pulses; one example is the air kerma of one pulse. Such a pulse can be produced, e.g. by X-ray flash units or high-intensity femtosecond-lasers. Other specifications are not applicable for much shorter pulses; one example is the time-dependent behaviour of the air kerma rate. This cannot be measurable for technical reasons as no suitable instrument is available, e.g. for pulses produced by a femtosecond-laser.
This document specifies the characteristics of reference pulsed radiation for calibrating and testing radiation protection dosemeters and dose rate meters with respect to their response to pulsed radiation. At this point, it is only concerned with the characteristics of single pulses. Single pulses are the most difficult for dosemeters to measure. Determining the dose for repeated pulses is easier, but still more difficult than for continuous radiation, i.e. the performance of the dosemeters when measuring repeated pulses lies between these extremes. The radiation characteristics includes the following:
- time-dependent behaviour of the air kerma rate of the pulse;
- time-dependent behaviour of the X-ray tube high voltage during the pulse;
- uniformity of the air kerma rate within a cross-sectional area of the radiation beam;
- air kerma of one radiation pulse;
- air kerma rate of the radiation pulse;
- repetition frequency.
This document does not define new radiation qualities but uses those radiation qualities specified in existing ISO and IEC standards. Instead, this document gives the link between the parameters for pulsed radiation and the parameters for continuous radiation specifying the radiation qualities. It does not specify specific values or series of values for the pulsed radiation field but specifies only those limits for the relevant pulsed radiation parameters that are required for calibrating dosemeters and dose rate meters and for determining their response depending on the said parameters.
The pulse parameters with respect to the phantom-related quantities were determined using conversion coefficients according to ISO 4037 (all parts). This is possible as the radiation qualities specified in existing ISO and IEC standards are used.
A given reference pulsed X-ray facility is characterized by the parameter ranges over which the full specifications and requirements according to this document are met. Therefore, not all reference pulsed X-ray facilities can produce pulses covering the same parameter ranges.
Edition
1
Published Date
2026-06-19
Status
PUBLISHED
Pages
17
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document is directly applicable to pulsed X-radiation with pulse duration of 0,1 ms up to 10 s. This range covers the whole range used in medical diagnostics at the time of publication. Some specifications can also be applicable for much shorter pulses; one example is the air kerma of one pulse. Such a pulse can be produced, e.g. by X-ray flash units or high-intensity femtosecond-lasers. Other specifications are not applicable for much shorter pulses; one example is the time-dependent behaviour of the air kerma rate. This cannot be measurable for technical reasons as no suitable instrument is available, e.g. for pulses produced by a femtosecond-laser.
This document specifies the characteristics of reference pulsed radiation for calibrating and testing radiation protection dosemeters and dose rate meters with respect to their response to pulsed radiation. At this point, it is only concerned with the characteristics of single pulses. Single pulses are the most difficult for dosemeters to measure. Determining the dose for repeated pulses is easier, but still more difficult than for continuous radiation, i.e. the performance of the dosemeters when measuring repeated pulses lies between these extremes. The radiation characteristics includes the following:
- time-dependent behaviour of the air kerma rate of the pulse;
- time-dependent behaviour of the X-ray tube high voltage during the pulse;
- uniformity of the air kerma rate within a cross-sectional area of the radiation beam;
- air kerma of one radiation pulse;
- air kerma rate of the radiation pulse;
- repetition frequency.
This document does not define new radiation qualities but uses those radiation qualities specified in existing ISO and IEC standards. Instead, this document gives the link between the parameters for pulsed radiation and the parameters for continuous radiation specifying the radiation qualities. It does not specify specific values or series of values for the pulsed radiation field but specifies only those limits for the relevant pulsed radiation parameters that are required for calibrating dosemeters and dose rate meters and for determining their response depending on the said parameters.
The pulse parameters with respect to the phantom-related quantities were determined using conversion coefficients according to ISO 4037 (all parts). This is possible as the radiation qualities specified in existing ISO and IEC standards are used.
A given reference pulsed X-ray facility is characterized by the parameter ranges over which the full specifications and requirements according to this document are met. Therefore, not all reference pulsed X-ray facilities can produce pulses covering the same parameter ranges.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 12749:2024 Nuclear energy, nuclear technologies, and radiological protection – Vocabulary – Part 3: Nuclear installations, processes and technologies
CDN $263.00 Add to cart -

ISO 22908:2020 Water quality – Radium 226 and Radium 228 – Test method using liquid scintillation counting
CDN $310.00 Add to cart -

ISO 12749:2022 Nuclear energy, nuclear technologies, and radiological protection – Vocabulary – Part 2: Radiological protection
CDN $86.00 Add to cart -

ISO 14146:2024 Radiological protection – Criteria and performance limits for the periodic evaluation of dosimetry services for external radiation
CDN $263.00 Add to cart







