
ISO 18107:2026
ISO 18107:2026 Variable refrigerant flow air-to-air conditioners and air-to-air heat pumps — Testing and calculating methods for seasonal performance factors and energy performance mapping approach
CDN $422.00
This publication was last reviewed and confirmed in 2026.
Variable refrigerant flow air-to-air conditioners and air-to-air heat pumps — Testing and calculating methods for seasonal performance factors and energy performance mapping approach
Description
This document specifies:
- the test conditions and test methods for determining capacity and efficiency ratings;
- calculation methods for seasonal performance.
This applies to factory made, electric mains operated, variable refrigerant flow air-cooled air conditioners and air-to-air heat pumps with a rated capacity above 12 kW for cooling or for heating if the product has no cooling function.
In this document, “heat pumps” means “air-to-air heat pumps” and “air conditioners” means “air-cooled air conditioners”.
This document establishes a method for determining global variable refrigerant flow (VRF) performance with annexes addressing specific national or regional deviations, such as regionally specific power or testing requirements.
This document does not apply to the testing and rating of:
- water-source heat pumps or water-cooled air conditioners;
- multi-split systems where each indoor unit has dedicated piping connected directly to the outdoor unit;
- individual assemblies not constituting a complete refrigeration system.
Edition
1
Published Date
2026-06-19
Status
PUBLISHED
Pages
140
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies:
- the test conditions and test methods for determining capacity and efficiency ratings;
- calculation methods for seasonal performance.
This applies to factory made, electric mains operated, variable refrigerant flow air-cooled air conditioners and air-to-air heat pumps with a rated capacity above 12 kW for cooling or for heating if the product has no cooling function.
In this document, “heat pumps” means “air-to-air heat pumps” and “air conditioners” means “air-cooled air conditioners”.
This document establishes a method for determining global variable refrigerant flow (VRF) performance with annexes addressing specific national or regional deviations, such as regionally specific power or testing requirements.
This document does not apply to the testing and rating of:
- water-source heat pumps or water-cooled air conditioners;
- multi-split systems where each indoor unit has dedicated piping connected directly to the outdoor unit;
- individual assemblies not constituting a complete refrigeration system.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 80004:2011 Nanotechnologies – Vocabulary – Part 7: Diagnostics and therapeutics for healthcare
CDN $124.00 Add to cart -

ISO 80004:2011 Nanotechnologies – Vocabulary – Part 5: Nano/bio interface
CDN $82.00 Add to cart -

ISO 80004:2020 Nanotechnologies – Vocabulary – Part 8: Nanomanufacturing processes
CDN $82.00 Add to cart -

ISO 20537:2025 Footwear – Identification of defects during visual inspection – Vocabulary
CDN $295.00 Add to cart







