ISO 19970:2025

ISO 19970:2025 Refrigerated hydrocarbon and non-petroleum based liquefied gaseous fuels — Metering of gas as fuel on LNG carriers during cargo transfer operations

CDN $186.00

This publication was last reviewed and confirmed in 2025.

Refrigerated hydrocarbon and non-petroleum based liquefied gaseous fuels — Metering of gas as fuel on LNG carriers during cargo transfer operations

SKU: 4bee234663f2 Category:

Description

This document specifies the minimum requirements to quantify boil-off gas (BOG) consumed on liquefied natural gas (LNG) carriers for their own functions, in particular for power generation and during cargo transfer operations.

This document provides requirements for the metering of BOG and the subsequent calorific value calculations, which can be taken into account when the energy transferred during cargo transfer is determined. This document also gives performance requirements and calibration of the elements included in the BOG measurement system.

This document, with some modifications, can also be applied to the measurement of BOG consumed by LNG carriers at sea.

Edition

2

Published Date

2026-06-18

Status

PUBLISHED

Pages

13

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies the minimum requirements to quantify boil-off gas (BOG) consumed on liquefied natural gas (LNG) carriers for their own functions, in particular for power generation and during cargo transfer operations.

This document provides requirements for the metering of BOG and the subsequent calorific value calculations, which can be taken into account when the energy transferred during cargo transfer is determined. This document also gives performance requirements and calibration of the elements included in the BOG measurement system.

This document, with some modifications, can also be applied to the measurement of BOG consumed by LNG carriers at sea.