
ISO 32543-3:2026
ISO 32543-3:2026 Non-destructive testing — Characteristics of focal spots in industrial X-ray systems — Part 3: Measurement of the effective focal spot size of mini and micro focus X-ray tubes
CDN $186.00
This publication was last reviewed and confirmed in 2026.
Non-destructive testing — Characteristics of focal spots in industrial X-ray systems — Part 3: Measurement of the effective focal spot size of mini and micro focus X-ray tubes
Description
This document specifies a method for the measurement of focal spot sizes within the range of 5 µm to 300 µm of X-ray systems up to and including 225 kV tube voltage. This determination is based on the evaluation of an image with a dedicated focal spot that has been radiographically recorded using an edge and evaluated with a digital method.
The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular its size and the two-dimensional intensity distribution as seen from the detector plane.
For the characterization of commercial X-ray tube types (i.e. for advertising or trade), the nominal values of Annex A are preferred.
NOTE The same procedure can be used at higher kilovoltages by agreement but the accuracy of the measurement can be poorer.
Edition
1
Published Date
2026-06-19
Status
PUBLISHED
Pages
14
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies a method for the measurement of focal spot sizes within the range of 5 µm to 300 µm of X-ray systems up to and including 225 kV tube voltage. This determination is based on the evaluation of an image with a dedicated focal spot that has been radiographically recorded using an edge and evaluated with a digital method.
The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular its size and the two-dimensional intensity distribution as seen from the detector plane.
For the characterization of commercial X-ray tube types (i.e. for advertising or trade), the nominal values of Annex A are preferred.
NOTE The same procedure can be used at higher kilovoltages by agreement but the accuracy of the measurement can be poorer.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 5078:2025 Management of terminology resources – Terminology extraction
CDN $251.00 Add to cart -

ISO 3833:1977 Road vehicles – Types – Terms and definitions
CDN $124.00 Add to cart -

ISO 80004:2020 Nanotechnologies – Vocabulary – Part 3: Carbon nano-objects
CDN $82.00 Add to cart -

ISO 80004:2011 Nanotechnologies – Vocabulary – Part 5: Nano/bio interface
CDN $82.00 Add to cart







