ISO 7383-3:2026
ISO 7383-3:2026 Fine bubble technology — Evaluation method for determining gas content in fine bubble dispersions in water — Part 3: Ozone content
CDN $259.00
This publication was last reviewed and confirmed in 2026.
Fine bubble technology — Evaluation method for determining gas content in fine bubble dispersions in water — Part 3: Ozone content
Description
This document specifies two evaluation methods for ozone content (total ozone, including ozone contained in ultrafine bubbles (UFBs) or microbubbles (MBs) and dissolved ozone) in UFB dispersions in water, namely, iodometric titration and UV photometry.
Iodometric titration is applicable as a well-established, high accuracy chemical procedure, particularly suitable for single-point determinations. The direct measurement range of this technique is typically 0,01 mg/l to 50 mg/l.
Ultraviolet (UV) photometry is applicable for rapid or continuous measurement and real-time monitoring. Its typical measurement range is from 0,075 mg/l to 200 mg/l, depending on instrument specification.
This document is applicable to industrial processes that require precise ozone dosing and control when MB or UFB systems are used.
NOTE This document does not involve the specific effects of ozone UFB dispersion applications. High concentrations of dissolved oxygen (DO), commonly found in water containing oxygen UFBs, can interfere with iodometric titration and lead to overestimation of ozone content. When extremely high ozone levels are expected, water containing oxygen UFBs can be used as the blank control.
Edition
1
Published Date
2026-09-16
Status
PUBLISHED
Pages
20
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This document specifies two evaluation methods for ozone content (total ozone, including ozone contained in ultrafine bubbles (UFBs) or microbubbles (MBs) and dissolved ozone) in UFB dispersions in water, namely, iodometric titration and UV photometry.
Iodometric titration is applicable as a well-established, high accuracy chemical procedure, particularly suitable for single-point determinations. The direct measurement range of this technique is typically 0,01 mg/l to 50 mg/l.
Ultraviolet (UV) photometry is applicable for rapid or continuous measurement and real-time monitoring. Its typical measurement range is from 0,075 mg/l to 200 mg/l, depending on instrument specification.
This document is applicable to industrial processes that require precise ozone dosing and control when MB or UFB systems are used.
NOTE This document does not involve the specific effects of ozone UFB dispersion applications. High concentrations of dissolved oxygen (DO), commonly found in water containing oxygen UFBs, can interfere with iodometric titration and lead to overestimation of ozone content. When extremely high ozone levels are expected, water containing oxygen UFBs can be used as the blank control.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 5157:2023 Textiles – Environmental aspects – Vocabulary
CDN $85.00 Add to cart -

ISO 23434:2021 Industrial trucks – Sustainability – Part 1: Vocabulary
CDN $85.00 Add to cart -

ISO 41011:2024 Facility management – Vocabulary
CDN $259.00 Add to cart -

ISO 34000:2023 Date and time – Vocabulary
CDN $85.00 Add to cart