ISO 8932-1:2025

ISO 8932-1:2025 Meteorology — Radiosonde — Part 1: Laboratory test method for calibration error of temperature sensor in radiosonde

CDN $125.00

This publication was last reviewed and confirmed in 2025.

Meteorology — Radiosonde — Part 1: Laboratory test method for calibration error of temperature sensor in radiosonde

SKU: 87497cd21b07 Categories: ,

Description

This document specifies a test method in terms of calibration error for radiosonde temperature sensors sampled from a batch of mass production, with varying temperature in laboratory setups at ground level pressure. This document elaborates on:

a)       the technical requirements for test chamber and reference thermometers as essential laboratory setups to evaluate the calibration errors of radiosonde temperature measurement;

b)       a test procedure including the installation of radiosondes in the test chamber, the operation of laboratory setups and the comparison between radiosonde and the temperature references for evaluating calibration errors of radiosonde temperature sensors for a temperature range of −85 °C1) to 50 °C at laboratory conditions; at

c)        a method for evaluating the uncertainties related to the references and the radiosonde sensors for the measured radiosonde temperature calibration error.

NOTE            Calibration error of radiosonde treated in this document forms only a part of the error in radiosonde sounding measurements. Regarding the errors involved in radiosonde temperature measurement on sounding, it is necessary to consider various errors as shown in Table 2 of Reference [ REF
Reference_ref_14 r h
7
08D0C9EA79F9BACE118C8200AA004BA90B0200000008000000110000005200650066006500720065006E00630065005F007200650066005F00310034000000
]; this document provides only a partial evaluation in laboratory tests.

1) Currently, the lowest possible temperature of commercially-available test chambers is more or less −75 °C. The temperature range can be adjusted depending on the capability of the test chambers.
Edition

1

Published Date

2026-06-19

Status

PUBLISHED

Pages

12

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a test method in terms of calibration error for radiosonde temperature sensors sampled from a batch of mass production, with varying temperature in laboratory setups at ground level pressure. This document elaborates on:

a)       the technical requirements for test chamber and reference thermometers as essential laboratory setups to evaluate the calibration errors of radiosonde temperature measurement;

b)       a test procedure including the installation of radiosondes in the test chamber, the operation of laboratory setups and the comparison between radiosonde and the temperature references for evaluating calibration errors of radiosonde temperature sensors for a temperature range of −85 °C1) to 50 °C at laboratory conditions; at

c)        a method for evaluating the uncertainties related to the references and the radiosonde sensors for the measured radiosonde temperature calibration error.

NOTE            Calibration error of radiosonde treated in this document forms only a part of the error in radiosonde sounding measurements. Regarding the errors involved in radiosonde temperature measurement on sounding, it is necessary to consider various errors as shown in Table 2 of Reference [ REF Reference_ref_14 r h 7 08D0C9EA79F9BACE118C8200AA004BA90B0200000008000000110000005200650066006500720065006E00630065005F007200650066005F00310034000000 ]; this document provides only a partial evaluation in laboratory tests.

1) Currently, the lowest possible temperature of commercially-available test chambers is more or less −75 °C. The temperature range can be adjusted depending on the capability of the test chambers.