Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

SPE-900-13

SPE-900-13 – Solar photovoltaic rooftop-installation best practices guideline

CDN $122.00

Solar photovoltaic rooftop-installation best practices guideline

Description

Preface This is the first edition of the CSA SPE-900, Solar photovoltaic rooftop-installation best practices guideline. CSA SPE-900 has been developed as a guideline, and does not contain any mandatory language. It provides guidance and best practices for solar photovoltaic rooftop-installation.  CSA Group acknowledges that the development of this Guideline was made possible, in part, by the financial support of the following: (a) Axis Property (b) BCHydro (c) Hydro Quebec (d) Manitoba Hydro (e) Ontario Ministry of Energy (f) SaskPower Scope 1.1 There is a need in the Canadian marketplace for guidance on solar photovoltaic rooftop installation, as photovoltaic modules are not currently addressed in many of the building codes. This guideline is intended to outline best practices for rooftop solar photovoltaic systems by addressing the following:  (a) structural analysis of the building itself resulting from the solar photovoltaic system installation  (b) structural analysis of the solar photovoltaic racking (c) flammability of rooftop solar photovoltaic mounting systems (d) preventing water penetration of the roofing system due to the installation of a solar photovoltaic system  (e) climbing hazards associated with solar photovoltaic system installations (f) avalanche hazards (due to snow and wind loads) associated with solar photovoltaic installation (g) safe roof access for first responders (i.e., fire fighters) in the event of an emergency or maintenance personnel (e.g., electricians, window cleaners, or other service personnel)  1.2 This guideline is intended to be used by solar photovoltaic system designers, installers, system owners, local building officials, fire departments, insurers, project financiers, etc.  1.3 The values given in SI (metric) units are the standard. Any values given in parentheses are for information only.  1.4 This guideline addresses rooftop solar photovoltaic systems only. It is applicable to residential, institutional, commercial, and industrial (ICI) buildings with either flat roofs or pitched roofs. While the focus is on rooftop-mounted systems, some of the principles described herein can be applied to photovoltaic systems mounted to facades, carports, awnings, sound barriers, and other building structures. This guideline will also examine different roofing materials and systems, including membranes, standing-seam metal roofing, steel high-rib roofing, steel shingle, asphalt, tile, slate, cedar shakes, and green roofs. Lastly, it will take into consideration the structure itself, including the structural systems and type of building materials (e.g., wood-frame rafters and joists, prefabricated wood trusses, structural steel beams and joists, and other systems in steel, masonry, concrete, and wood).  1.5 It is important to note that this guideline does not address solar photovoltaic system electrical hazards, as these issues are addressed by the Canadian Electrical Code, Part I (CEC). However, this guideline does direct the user to the appropriate sections of the CEC as required. In addition, this guideline does not address building-integrated solar photovoltaic systems (BIPV).  1.6 Reference to the National Building Code of Canada (NBCC) implies the adopted versions of the National Building Code of Canada by provincial and regional authorities throughout Canada.  1.7 It is advisable to contact local municipalities (or building authority) to determine electrical and structural permit requirements for the installation of photovoltaic rooftop installations for the photovoltaic system and the building itself. Requirements for zoning, new developments, and photovoltaic design may vary.  1.8 In this guideline, “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the guideline; and “can” is used to express possibility or capability.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

78

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of the CSA SPE-900, Solar photovoltaic rooftop-installation best practices guideline. CSA SPE-900 has been developed as a guideline, and does not contain any mandatory language. It provides guidance and best practices for solar photovoltaic rooftop-installation.  CSA Group acknowledges that the development of this Guideline was made possible, in part, by the financial support of the following: (a) Axis Property (b) BCHydro (c) Hydro Quebec (d) Manitoba Hydro (e) Ontario Ministry of Energy (f) SaskPower Scope 1.1 There is a need in the Canadian marketplace for guidance on solar photovoltaic rooftop installation, as photovoltaic modules are not currently addressed in many of the building codes. This guideline is intended to outline best practices for rooftop solar photovoltaic systems by addressing the following:  (a) structural analysis of the building itself resulting from the solar photovoltaic system installation  (b) structural analysis of the solar photovoltaic racking (c) flammability of rooftop solar photovoltaic mounting systems (d) preventing water penetration of the roofing system due to the installation of a solar photovoltaic system  (e) climbing hazards associated with solar photovoltaic system installations (f) avalanche hazards (due to snow and wind loads) associated with solar photovoltaic installation (g) safe roof access for first responders (i.e., fire fighters) in the event of an emergency or maintenance personnel (e.g., electricians, window cleaners, or other service personnel)  1.2 This guideline is intended to be used by solar photovoltaic system designers, installers, system owners, local building officials, fire departments, insurers, project financiers, etc.  1.3 The values given in SI (metric) units are the standard. Any values given in parentheses are for information only.  1.4 This guideline addresses rooftop solar photovoltaic systems only. It is applicable to residential, institutional, commercial, and industrial (ICI) buildings with either flat roofs or pitched roofs. While the focus is on rooftop-mounted systems, some of the principles described herein can be applied to photovoltaic systems mounted to facades, carports, awnings, sound barriers, and other building structures. This guideline will also examine different roofing materials and systems, including membranes, standing-seam metal roofing, steel high-rib roofing, steel shingle, asphalt, tile, slate, cedar shakes, and green roofs. Lastly, it will take into consideration the structure itself, including the structural systems and type of building materials (e.g., wood-frame rafters and joists, prefabricated wood trusses, structural steel beams and joists, and other systems in steel, masonry, concrete, and wood).  1.5 It is important to note that this guideline does not address solar photovoltaic system electrical hazards, as these issues are addressed by the Canadian Electrical Code, Part I (CEC). However, this guideline does direct the user to the appropriate sections of the CEC as required. In addition, this guideline does not address building-integrated solar photovoltaic systems (BIPV).  1.6 Reference to the National Building Code of Canada (NBCC) implies the adopted versions of the National Building Code of Canada by provincial and regional authorities throughout Canada.  1.7 It is advisable to contact local municipalities (or building authority) to determine electrical and structural permit requirements for the installation of photovoltaic rooftop installations for the photovoltaic system and the building itself. Requirements for zoning, new developments, and photovoltaic design may vary.  1.8 In this guideline, "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the guideline; and "can" is used to express possibility or capability.

Previous Editions

Can’t find what you are looking for?

Please contact us at: