Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

Z320-11 (R2026)

Z320-11 (R2026) – Building commissioning

CDN $362.00

Building commissioning

Description

Preface This is the first edition of CSA Z320, Building commissioning . This Standard provides guidelines for the commissioning of buildings and all related building systems, and has been developed to deal with buildings and/or their major systems as a whole, rather than as separate individual stand-alone components. It applies to new construction and to renovations of existing buildings or facilities.  Scope 1.1 General  1.1.1 This Standard provides guidelines for the commissioning of buildings and all related building systems. It applies to new construction and to renovations of existing facilities. It does not apply to operational commissioning of equipment and systems installed by the owner or others.  1.1.2 This Standard is intended to assist the commissioning team in the preparation and implementation of a commissioning plan. This plan specifies commissioning requirements for newly installed or renovated building systems and includes, but is not limited to, descriptions of the following:  (a) the commissioning process;  (b) the resources required to complete commissioning;  (c) the responsibilities of the commissioning team; and  (d) the sequence and integration of commissioning activities.  1.2 Specific systems  1.2.1 General  The systems covered in this Standard are classified as  (a) architectural;  (b) vertical and horizontal transportation;  (c) electrical;  (d) mechanical; and  (e) control and integration.  1.2.2 Site services  For the purposes of this Standard, commissioning will be limited to the building enclosure and not include site services outside the building. Any exceptions will be identified in the commissioning plan.  1.3 Terminology  In CSA standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.  Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.  Notes to tables and figures are considered part of the table or figure and may be written as requirements.  Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

90

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of CSA Z320, Building commissioning . This Standard provides guidelines for the commissioning of buildings and all related building systems, and has been developed to deal with buildings and/or their major systems as a whole, rather than as separate individual stand-alone components. It applies to new construction and to renovations of existing buildings or facilities.  Scope 1.1 General  1.1.1 This Standard provides guidelines for the commissioning of buildings and all related building systems. It applies to new construction and to renovations of existing facilities. It does not apply to operational commissioning of equipment and systems installed by the owner or others.  1.1.2 This Standard is intended to assist the commissioning team in the preparation and implementation of a commissioning plan. This plan specifies commissioning requirements for newly installed or renovated building systems and includes, but is not limited to, descriptions of the following:  (a) the commissioning process;  (b) the resources required to complete commissioning;  (c) the responsibilities of the commissioning team; and  (d) the sequence and integration of commissioning activities.  1.2 Specific systems  1.2.1 General  The systems covered in this Standard are classified as  (a) architectural;  (b) vertical and horizontal transportation;  (c) electrical;  (d) mechanical; and  (e) control and integration.  1.2.2 Site services  For the purposes of this Standard, commissioning will be limited to the building enclosure and not include site services outside the building. Any exceptions will be identified in the commissioning plan.  1.3 Terminology  In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.  Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.  Notes to tables and figures are considered part of the table or figure and may be written as requirements.  Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.