Search
×
FR

Placeholder headline

This is just a placeholder headline

API TR 5C3: Calculating Performance Properties of Pipe Used as Casing or Tubing

$

422

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 671: Special Purpose Couplings for Petroleum, Chemical and Gas Industry Services

$

502

BUY NOW

Placeholder headline

This is just a placeholder headline

Technical Report API TBD-10: Chapter 10 Surface and Interfacial Tension

$

176

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 671: Special Purpose Couplings for Petroleum, Chemical and Gas Industry Services: Errata 2

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

MSS SP-44-2026: Steel Pipeline Flanges

$

450

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 576: Inspection of Pressure-relieving Devices

$

460

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 591: Process Valve Qualification Procedure

$

226

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 576: Inspection of Pressure-relieving Devices: Addendum 1

$

0

BUY NOW

ISO 11138:2017

ISO 11138:2017 Sterilization of health care products – Biological indicators – Part 1: General requirements

CDN $312.00

SKU: bc33892b26d2 Categories: ,

Description

Ôªø

ISO 11138-1:2017 specifies general requirements for production, labelling, test methods and performance characteristics of biological indicators, including inoculated carriers and suspensions, and their components, to be used in the validation and routine monitoring of sterilization processes.

ISO 11138-1:2017 specifies basic and common requirements that are applicable to all parts of ISO 11138. Requirements for biological indicators for particular specified processes are provided in the relevant parts of ISO 11138. If no specific subsequent part is provided, this document applies.

NOTE National or regional regulations can apply.

ISO 11138-1:2017 does not apply to microbiological test systems for processes that rely on physical removal of microorganisms, e.g. filtration processes or processes that combine physical and/or mechanical removal with microbiological inactivation, such as use of washer disinfectors or flushing and steaming of pipelines. This document, however, can contain elements relevant to such microbiological test systems.

Edition

3

Published Date

2017-03-03

Status

PUBLISHED

Pages

41

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Ôªø

ISO 11138-1:2017 specifies general requirements for production, labelling, test methods and performance characteristics of biological indicators, including inoculated carriers and suspensions, and their components, to be used in the validation and routine monitoring of sterilization processes.

ISO 11138-1:2017 specifies basic and common requirements that are applicable to all parts of ISO 11138. Requirements for biological indicators for particular specified processes are provided in the relevant parts of ISO 11138. If no specific subsequent part is provided, this document applies.

NOTE National or regional regulations can apply.

ISO 11138-1:2017 does not apply to microbiological test systems for processes that rely on physical removal of microorganisms, e.g. filtration processes or processes that combine physical and/or mechanical removal with microbiological inactivation, such as use of washer disinfectors or flushing and steaming of pipelines. This document, however, can contain elements relevant to such microbiological test systems.

Previous Editions

Can’t find what you are looking for?

Please contact us at: