REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 22.6: Testing Protocols for Gas Chromatographs : Reaffirmed

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1174: Onshore Hazardous Liquid Pipeline Emergency Preparedness and Response : Reaffirmed

$

182

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 624: Type Testing of Rising Stem Valves Equipped with Flexible Graphite Packing for Fugitive

$

171

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 20G: Welding Services for Equipment used in the Petroleum and Natural Gas Industry : Reaffirmed

$

164

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 624: Errata 2

$

0.00

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems

$

167

BUY NOW

ISO 11138:2017

ISO 11138:2017 Sterilization of health care products – Biological indicators – Part 1: General requirements

CDN $312.00

SKU: bc33892b26d2 Categories: ,

Description

Ôªø

ISO 11138-1:2017 specifies general requirements for production, labelling, test methods and performance characteristics of biological indicators, including inoculated carriers and suspensions, and their components, to be used in the validation and routine monitoring of sterilization processes.

ISO 11138-1:2017 specifies basic and common requirements that are applicable to all parts of ISO 11138. Requirements for biological indicators for particular specified processes are provided in the relevant parts of ISO 11138. If no specific subsequent part is provided, this document applies.

NOTE National or regional regulations can apply.

ISO 11138-1:2017 does not apply to microbiological test systems for processes that rely on physical removal of microorganisms, e.g. filtration processes or processes that combine physical and/or mechanical removal with microbiological inactivation, such as use of washer disinfectors or flushing and steaming of pipelines. This document, however, can contain elements relevant to such microbiological test systems.

Edition

3

Published Date

2017-03-03

Status

PUBLISHED

Pages

41

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Ôªø

ISO 11138-1:2017 specifies general requirements for production, labelling, test methods and performance characteristics of biological indicators, including inoculated carriers and suspensions, and their components, to be used in the validation and routine monitoring of sterilization processes.

ISO 11138-1:2017 specifies basic and common requirements that are applicable to all parts of ISO 11138. Requirements for biological indicators for particular specified processes are provided in the relevant parts of ISO 11138. If no specific subsequent part is provided, this document applies.

NOTE National or regional regulations can apply.

ISO 11138-1:2017 does not apply to microbiological test systems for processes that rely on physical removal of microorganisms, e.g. filtration processes or processes that combine physical and/or mechanical removal with microbiological inactivation, such as use of washer disinfectors or flushing and steaming of pipelines. This document, however, can contain elements relevant to such microbiological test systems.

Previous Editions

Can’t find what you are looking for?

Please contact us at: