ISO 28581:2012
ISO 28581:2012 Water quality – Determination of selected non-polar substances – Method using gas chromatography with mass spectrometric detection (GC-MS)
CDN $251.00
Description
This Technical Specification specifies a method for the determination by gas chromatography with mass
spectrometric detection (GC-MS) of polycyclic hydrocarbons and pesticide residues in drinking water and ground
water at mass concentrations above 0,005 μg/l and surface water and waste water at mass concentrations
above 0,01 μg/l (for each single compound).
This method can apply to non-polar substances other than polycylic aromatic hydrocarbons (PAH) and pesticide
residues. However, it is necessary to verify the applicability of this method for these compounds.
NOTE 1 A potentially suitable method for this verification is specified in ISO/TS 13530.[3]
This Technical Specification can be used for samples containing up to 150 mg/l of suspended matter.
NOTE 2 Determination of PAH using GC-MS lies within the scope of ISO 28540.[9]
Edition
1
Published Date
2012-02-06
Status
PUBLISHED
Pages
25
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
This Technical Specification specifies a method for the determination by gas chromatography with mass
spectrometric detection (GC-MS) of polycyclic hydrocarbons and pesticide residues in drinking water and ground
water at mass concentrations above 0,005 μg/l and surface water and waste water at mass concentrations
above 0,01 μg/l (for each single compound).
This method can apply to non-polar substances other than polycylic aromatic hydrocarbons (PAH) and pesticide
residues. However, it is necessary to verify the applicability of this method for these compounds.
NOTE 1 A potentially suitable method for this verification is specified in ISO/TS 13530.[3]
This Technical Specification can be used for samples containing up to 150 mg/l of suspended matter.
NOTE 2 Determination of PAH using GC-MS lies within the scope of ISO 28540.[9]
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 21676:2018 Water quality – Determination of the dissolved fraction of selected active pharmaceutical ingredients, transformation products and other organic substances in water and treated waste water – Method using high performance liquid chromatography and mass spectrometric detection (HPLC-MS/MS or -HRMS) after direct injection
CDN $295.00 Add to cart -

ISO 25101:2009 Water quality – Determination of perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) – Method for unfiltered samples using solid phase extraction and liquid chromatography/mass spectrometry
CDN $251.00 Add to cart -

ISO 15680:2003 Water quality – Gas-chromatographic determination of a number of monocyclic aromatic hydrocarbons, naphthalene and several chlorinated compounds using purge-and-trap and thermal desorption
CDN $295.00 Add to cart -

ISO 15586:2003 Water quality – Determination of trace elements using atomic absorption spectrometry with graphite furnace
CDN $251.00 Add to cart