ISO 11311:2011 specifies common reference critical values (of which the effective neutron multiplication factor, keff, is equal to 1) for homogeneous water-moderated plutonium-uranium oxide mixtures based on an inter-code comparison of calculated critical values.
It is applicable to operations with unirradiated mixed uranium-plutonium oxide (MOX) outside nuclear reactors.
A classical validation approach for these systems is difficult because of the paucity of critical experiments for MOX fuel.
Various reference systems, in terms of isotopic compositions, thicknesses of water reflection, and densities of oxide are evaluated by different combinations of calculation codes and nuclear data libraries (i.e. different calculation schemes).
The critical values defined in ISO 11311:2011 are the lowest of those calculated by each of these calculation schemes and accepted as credible.
The values in ISO 11311:2011 are reference values and not absolute critical values.
Edition
1
Published Date
2011-07-05
Status
PUBLISHED
Pages
13
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
ISO 11311:2011 specifies common reference critical values (of which the effective neutron multiplication factor, keff, is equal to 1) for homogeneous water-moderated plutonium-uranium oxide mixtures based on an inter-code comparison of calculated critical values.
It is applicable to operations with unirradiated mixed uranium-plutonium oxide (MOX) outside nuclear reactors.
A classical validation approach for these systems is difficult because of the paucity of critical experiments for MOX fuel.
Various reference systems, in terms of isotopic compositions, thicknesses of water reflection, and densities of oxide are evaluated by different combinations of calculation codes and nuclear data libraries (i.e. different calculation schemes).
The critical values defined in ISO 11311:2011 are the lowest of those calculated by each of these calculation schemes and accepted as credible.
The values in ISO 11311:2011 are reference values and not absolute critical values.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

ISO 16966:2013 Nuclear energy – Nuclear fuel technology – Theoretical activation calculation method to evaluate the radioactivity of activated waste generated at nuclear reactors
CDN $312.00 Add to cart -

ISO 18213:2009 Nuclear fuel technology – Tank calibration and volume determination for nuclear materials accountancy – Part 3: Statistical methods
CDN $312.00 Add to cart -

ISO 18256:2019 Nuclear fuel technology – Dissolution of plutonium dioxide-containing materials – Part 2: Dissolution of MOX pellets and powders
CDN $115.00 Add to cart -

ISO 16795:2024 Nuclear energy – Determination of Gd2O3 content in pellets containing uranium oxide by X-ray fluorescence spectrometry