CAN/CSA-E60730-2-10:13 (R2023)
CAN/CSA-E60730-2-10:13 (R2023) – Automatic electrical controls for household and similar use – Part 2-10: Particular requirements for motor-starting relays (Adopted IEC 60730-2- 10:2006, second edition, 2006-10, with Canadian deviations) | Dispositifs de commande électrique automatiques à usage domestique et analogue – Partie 2-10: Règles particulières pour les relais électriques de démarrage de moteur (norme CEI 60730-2-10-2006 adoptée, deuxième édition, 2006-10, avec exigences propres au Canada)
CDN $114.00
Automatic electrical controls for household and similar use – Part 2-10: Particular requirements for motor-starting relays (Adopted IEC 60730-2- 10:2006, second edition, 2006-10, with Canadian deviations) | Dispositifs de commande électrique automatiques à usage domestique et analogue – Partie 2-10: Règles particulières pour les relais électriques de démarrage de moteur (norme CEI 60730-2-10-2006 adoptée, deuxième édition, 2006-10, avec exigences propres au Canada)
Description
CSA Preface This is the second edition of CAN/CSA-E60730-2-10, Automatic electrical controls for household and similar use – Part 2-10: Particular requirements for motor-starting relays, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60730-2-10 (second edition, 2006-10). It supersedes the previous edition published in 1994 as CAN/CSA-E730-2-10, Automatic electrical controls for household and similar use – Part 2: Particular requirements for electrically operated motor starting relays (adopted IEC 730-2-10:1991). This Standard is intended to be used in conjunction with CAN/CSA-E60730-1:02, Automatic electrical controls for household and similar use – Part 1: General requirements (adopted IEC 60730-1:1999, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on International Standards, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been approved as a National Standard of Canada by the Standards Council of Canada. Scope and normative references This clause of Part 1 is applicable except as follows: 1.1 Replacement: This part of IEC 60730 applies to controls for automatically controlling the starting windings of single phase motors associated with equipment for household and similar use. This standard applies to motor-starting relays using NTC or PTC thermistors, additional requirements for which are contained in Annex J. 1.1.1 This standard applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety, and to the testing of motor-starting relays used in, or in association with, household or similar equipment. Motor-starting relays for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. This standard does not apply to motor-starting relays designed exclusively for industrial applications. Throughout this standard, the word “equipment” means “appliance and equipment”. The words “starting relay” mean “motor-starting relay”. 1.1.2 This standard applies to starting relays incorporating electronic devices and starting relays using thermistor elements, thermal elements and magnetic elements. 1.1.3 This standard does not apply to general purpose relays or to contactors and motor starters of the type covered by the IEC 60947 series1. This standard does not apply to mechanical timers or mechanically operated motor-starting devices. 1.1.4 This standard applies to manual controls when such are electrically and/or mechanically integral with starting relays. Requirements for manual switches not forming part of a starting relay are contained in IEC 61058-1. ——————————————————————————————————————————– Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-E60730-2-10, Dispositifs de commande électrique automatiques à usage domestique et analogue – Partie 2-10 : Règles particulières pour les relais électriques de démarrage de moteur . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme CEI (Commission Électrotechnique Internationale) 60730-2-10 (deuxième édition, 2006-10) qui porte le même titre. Cette norme remplace l’édition antérieure publiée en 1994 qui portait la désignation CAN/CSA-E730-2-10 (norme CEI 730-2-10:1991 adoptée). Cette norme est conçue pour être utilisée avec la CAN/CSA-E60730-1:02, Dispositifs de commande électrique automatiques à usage domestique et analogue – Partie 1 : Règles générales (norme CEI 60730-1:1999 adoptée, avec exigences propres au Canada). Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption au Canada par le Comité technique CSA sur les normes internationales, sous l’autorité du Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité et a été officiellement approuvée par le Comité technique. Cette norme a été approuvée en tant que Norme nationale du Canada par le Conseil canadien des normes. Domaine d’application et références normatives L’article de la Partie 1 s’applique avec les exceptions suivantes: 1.1 Remplacement: La présente partie de la CEI 60730 est applicable aux dispositifs de commande qui contrôlent automatiquement les enroulements de démarrage des moteurs monophasés associés au matériel àusage domestique et analogue. La présente norme s’applique aux relais de démarrage des moteurs utilisant des thermistances CTN ou CTP, dont les exigences additionnelles sont contenues à l’Annexe J. 1.1.1 La présente norme s’applique à la sécurité intrinsèque, aux valeurs de fonctionnement, aux temps de fonctionnement et aux séquences de fonctionnement dans la mesure où ils interviennent dans la sécurité du matériel, ainsi qu’aux essais de relais de démarrage des moteurs utilisés dans du matériel électrodomestique et analogue ou avec celui-ci. Les relais de démarrage des moteurs pour matériels non prévus pour un usage domestique normal, mais qui peuvent néanmoins être utilisés par le public, tel que le matériel prévu pour être utilisé par des personnes inexpérimentées dans les magasins, l’industrie légère et dans les fermes, sont du domaine de la présente norme. La présente norme ne s’applique pas aux relais de démarrage des moteurs conçus exclusivement pour des applications industrielles. Partout où il est utilisé dans la présente norme, le terme “matériel” signifie “matériel et équipement”. L’expression “relais de démarrage” signifie “relais de démarrage de moteur”. 1.1.2 La présente norme s’applique aux relais de démarrage à dispositifs électroniques incorporés et aux relais de démarrage utilisant des éléments de thermistance, des éléments thermiques et des éléments magnétiques. 1.1.3 La présente norme ne s’applique pas aux relais ou aux contacteurs à usage général et aux démarreurs de moteurs de type couvert par la série CEI 609471. La présente norme ne s’applique pas aux minuteries mécaniques ou aux dispositifs de démarrage de moteur agissant mécaniquement. 1.1.4 La présente norme s’applique aux dispositifs de commande manuelle dans la mesure où ils font partie intégrante, électriquement et/ou mécaniquement, de relais de démarrage. Les exigences pour les interrupteurs manuels ne faisant pas partie d’un relais de démarrage sont contenues dans la CEI 61058-1.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
44
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is the second edition of CAN/CSA-E60730-2-10, Automatic electrical controls for household and similar use - Part 2-10: Particular requirements for motor-starting relays, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60730-2-10 (second edition, 2006-10). It supersedes the previous edition published in 1994 as CAN/CSA-E730-2-10, Automatic electrical controls for household and similar use - Part 2: Particular requirements for electrically operated motor starting relays (adopted IEC 730-2-10:1991). This Standard is intended to be used in conjunction with CAN/CSA-E60730-1:02, Automatic electrical controls for household and similar use - Part 1: General requirements (adopted IEC 60730-1:1999, with Canadian deviations). This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on International Standards, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been approved as a National Standard of Canada by the Standards Council of Canada. Scope and normative references This clause of Part 1 is applicable except as follows: 1.1 Replacement: This part of IEC 60730 applies to controls for automatically controlling the starting windings of single phase motors associated with equipment for household and similar use. This standard applies to motor-starting relays using NTC or PTC thermistors, additional requirements for which are contained in Annex J. 1.1.1 This standard applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety, and to the testing of motor-starting relays used in, or in association with, household or similar equipment. Motor-starting relays for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. This standard does not apply to motor-starting relays designed exclusively for industrial applications. Throughout this standard, the word "equipment" means "appliance and equipment". The words "starting relay" mean "motor-starting relay". 1.1.2 This standard applies to starting relays incorporating electronic devices and starting relays using thermistor elements, thermal elements and magnetic elements. 1.1.3 This standard does not apply to general purpose relays or to contactors and motor starters of the type covered by the IEC 60947 series1. This standard does not apply to mechanical timers or mechanically operated motor-starting devices. 1.1.4 This standard applies to manual controls when such are electrically and/or mechanically integral with starting relays. Requirements for manual switches not forming part of a starting relay are contained in IEC 61058-1. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-E60730-2-10, Dispositifs de commande électrique automatiques à usage domestique et analogue - Partie 2-10 : Règles particulières pour les relais électriques de démarrage de moteur . Il s'agit de l'adoption, avec exigences propres au Canada, de la norme CEI (Commission Électrotechnique Internationale) 60730-2-10 (deuxième édition, 2006-10) qui porte le même titre. Cette norme remplace l'édition antérieure publiée en 1994 qui portait la désignation CAN/CSA-E730-2-10 (norme CEI 730-2-10:1991 adoptée). Cette norme est conçue pour être utilisée avec la CAN/CSA-E60730-1:02, Dispositifs de commande électrique automatiques à usage domestique et analogue - Partie 1 : Règles générales (norme CEI 60730-1:1999 adoptée, avec exigences propres au Canada). Cette norme est jugée convenable à l'évaluation de la conformité selon le domaine d'application établi dans la norme. Cette norme a été révisée en vue de son adoption au Canada par le Comité technique CSA sur les normes internationales, sous l’autorité du Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité et a été officiellement approuvée par le Comité technique. Cette norme a été approuvée en tant que Norme nationale du Canada par le Conseil canadien des normes. Domaine d'application et références normatives L'article de la Partie 1 s'applique avec les exceptions suivantes: 1.1 Remplacement: La présente partie de la CEI 60730 est applicable aux dispositifs de commande qui contrôlent automatiquement les enroulements de démarrage des moteurs monophasés associés au matériel àusage domestique et analogue. La présente norme s'applique aux relais de démarrage des moteurs utilisant des thermistances CTN ou CTP, dont les exigences additionnelles sont contenues à l'Annexe J. 1.1.1 La présente norme s'applique à la sécurité intrinsèque, aux valeurs de fonctionnement, aux temps de fonctionnement et aux séquences de fonctionnement dans la mesure où ils interviennent dans la sécurité du matériel, ainsi qu'aux essais de relais de démarrage des moteurs utilisés dans du matériel électrodomestique et analogue ou avec celui-ci. Les relais de démarrage des moteurs pour matériels non prévus pour un usage domestique normal, mais qui peuvent néanmoins être utilisés par le public, tel que le matériel prévu pour être utilisé par des personnes inexpérimentées dans les magasins, l'industrie légère et dans les fermes, sont du domaine de la présente norme. La présente norme ne s'applique pas aux relais de démarrage des moteurs conçus exclusivement pour des applications industrielles. Partout où il est utilisé dans la présente norme, le terme "matériel" signifie "matériel et équipement". L'expression "relais de démarrage" signifie "relais de démarrage de moteur". 1.1.2 La présente norme s'applique aux relais de démarrage à dispositifs électroniques incorporés et aux relais de démarrage utilisant des éléments de thermistance, des éléments thermiques et des éléments magnétiques. 1.1.3 La présente norme ne s'applique pas aux relais ou aux contacteurs à usage général et aux démarreurs de moteurs de type couvert par la série CEI 609471. La présente norme ne s'applique pas aux minuteries mécaniques ou aux dispositifs de démarrage de moteur agissant mécaniquement. 1.1.4 La présente norme s'applique aux dispositifs de commande manuelle dans la mesure où ils font partie intégrante, électriquement et/ou mécaniquement, de relais de démarrage. Les exigences pour les interrupteurs manuels ne faisant pas partie d'un relais de démarrage sont contenues dans la CEI 61058-1.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61347-2-3:23 – Lamp control gear — Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (Adopted IEC 61347-2-3:2011, edition 2:2011 consolidated with amendment 1:2016, with Canadian deviations) | Appareillages de lampes — Partie 2-3 : Exigences particulières pour les appareillages électroniques alimentés en courant alternatif et/ou en courant continu pour lampes fluorescentes (norme IEC 61347-2-3:2011 adoptée, édition 2:2011 consolidée par l’amendement 1:2016, avec exigences propres au Canada)
CDN $620.00 Add to cart -

CSA G12:14 (R2024) – Zinc-coated steel wire strand
CDN $136.00 Add to cart -

CSA E61951-2:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA E61959:14 (R2024) – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Mechanical tests for sealed portable secondary cells and batteries (Adopted IEC 61959:2004, first edition, 2004-01, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide – Essais mécaniques pour accumulateurs portables étanches (norme CEI 61959:2004 adoptée, première édition, 2004-01, avec exigences propres au Canada)
CDN $56.00 Add to cart