
CAN/CSA-C22.2 NO. 60601-1-6:11 + A1:15 + A2:21 (R2026) (CONSOLIDATED)
CAN/CSA-C22.2 NO. 60601-1-6:11 + A1:15 + A2:21 (R2026) (CONSOLIDATED) – Medical electrical equipment – Part 1-6: General requirements for basic safety and essential performance – Collateral standard: Usability (Adopted IEC 60601-1-6:2010, third edition, 2010-01, consolidated with amendment 1:2013 and amendment 2:2020, with Canadian deviations) | Appareils électromédicaux – Partie 1-6: Exigences générales pour la sécurité de base et les performances essentielles – Norme collatérale: Aptitude à l’utilisation (norme IEC 60601-1-6:2010 adoptée, troisième édition, 2010-01, consolidée par l’amendement 1:2013 et l’amendement 2:2020, avec exigences propres au Canada)
CDN $656.00
Medical electrical equipment – Part 1-6: General requirements for basic safety and essential performance – Collateral standard: Usability (Adopted IEC 60601-1-6:2010, third edition, 2010-01, consolidated with amendment 1:2013 and amendment 2:2020, with Canadian deviations) | Appareils électromédicaux – Partie 1-6: Exigences générales pour la sécurité de base et les performances essentielles – Norme collatérale: Aptitude à l’utilisation (norme IEC 60601-1-6:2010 adoptée, troisième édition, 2010-01, consolidée par l’amendement 1:2013 et l’amendement 2:2020, avec exigences propres au Canada)
Description
CSA Preface This is consolidated edition 3.2 of CAN/CSA-C22.2 No. 60601-1-6, Medical electrical equipment — Part 1-6: General requirements for basic safety and essential performance — Collateral standard: Usability , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-6 (edition 3:2010 consolidated with Amendment 1:2013 and Amendment 2:2020). It supersedes the second edition, published in 2008 as CAN/CSA-C22.2 No. 60601-1-6 (adopted IEC 60601-1-6:2006). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as “CAN/CSA-C22.2 No. 60601-1-6” throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). Where differences exist between this consolidated edition and the published edition and its amendments, those documents will take precedence. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Applications of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health Care Technology and Systems. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object 1.1 * Scope This International Standard specifies a PROCESS for a MANUFACTURER to analyse, specify, develop and evaluate the USABILITY, as it relates to BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT, hereafter referred to as ME EQUIPMENT. This USABILITY ENGINEERING PROCESS assesses and mitigates RISKS caused by USABILITY problems associated with CORRECT USE and USE ERRORS, i.e., NORMAL USE. It can be used to identify but does not assess or mitigate RISKS associated with ABNORMAL USE. If the USABILITY ENGINEERING PROCESS detailed in this collateral standard has been complied with, then the USABILITY of ME EQUIPMENT as it relates to BASIC SAFETY and ESSENTIAL PERFORMANCE is presumed to be acceptable, unless there is OBJECTIVE EVIDENCE to the contrary. NOTE Such OBJECTIVE EVIDENCE can subsequently originate from POST-PRODUCTION surveillance. 1.2 Object The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards. ——————————————————————————————————————————– Préface CSA Ce document constitue l’édition 3.2 consolidée de CAN/CSA-C22.2 nº 60601-1-6, Appareils électromédicaux — Partie 1-6 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Aptitude à l’utilisation. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60601-1-6 (édition 3:2010 consolidée par l’amendement 1:2013 et l’amendement 2:2020), qui porte le même titre. Cette norme remplace la deuxième édition publiée en 2008 qui portait la désignation CAN/CSA-C22.2 nº 60601-1-6 (norme IEC 60601-1-6:2006 adoptée). Il fait partie d’une série de normes publiées par Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé « CAN/CSA-C22.2 nº 60601-1-6 ». Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C22.2 nº 60601-1:14, Appareils électromédicaux — Partie 1 : Exigences générales pour la sécurité de base et les performances essentielles (norme IEC 60601-1:2005 adoptée, avec exigences propres au Canada), y compris l’amendement 1:2012). Lorsqu’il y a des différences entre cette édition consolidée et l’édition publiée et ses amendements, ces derniers auront préséance. Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption au Canada par le Comité technique CSA sur les produits commerciaux et grand public, sous l’autorité du Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité, et a été officiellement approuvée par le Comité technique. En raison de son contenu médical, la norme a également été approuvée par le Comité technique CSA sur les installations électriques dans les établissements de santé, sous l’autorité du Comité directeur stratégique CSA sur la technologie et les systèmes de soins de santé. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes relatives aux Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application et objet 1.1 * Domaine d’application La présente Norme internationale spécifie un PROCESSUS destiné à un FABRICANT pour analyser, spécifier, élaborer et évaluer l’APTITUDE A L’UTILISATION, ayant trait à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS ELECTROMEDICAUX, désignés ci-après sous le terme d’APPAREILS EM. Ce PROCESSUS D’INGENIERIE DE L’APTITUDE A L’UTILISATION évalue et réduit les RISQUES provoqués par les problèmes D’APTITUDE A L’UTILISATION associés à une UTILISATION CORRECTE et à des ERREURS D’UTILISATION, c’est-à-dire une UTILISATION NORMALE. Il peut être utilisé pour identifier mais n’évalue pas et ne réduit pas les RISQUES associés à une UTILISATION ANORMALE. Si le PROCESSUS D’INGÉNIERIE D’APTITUDE À L’UTILISATION décrit en détail dans la présente norme collatérale a été respecté, l’APTITUDE À L’UTILISATION des APPAREILS EM, dans la mesure où elle a trait à la SÉCURITÉ DE BASE et aux PERFORMANCES ESSENTIELLES, est présumée acceptable, sauf s’il existe une PREUVE TANGIBLE du contraire. NOTE Cette PREUVE TANGIBLE peut provenir ultérieurement du contrôle de la POSTPRODUCTION. 1.2 Objet La présente norme collatérale est destinée à spécifier des exigences générales qui viennent compléter celles de la norme générale et à servir de base pour les normes particulières.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
118
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
CSA Preface This is consolidated edition 3.2 of CAN/CSA-C22.2 No. 60601-1-6, Medical electrical equipment — Part 1-6: General requirements for basic safety and essential performance — Collateral standard: Usability , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-1-6 (edition 3:2010 consolidated with Amendment 1:2013 and Amendment 2:2020). It supersedes the second edition, published in 2008 as CAN/CSA-C22.2 No. 60601-1-6 (adopted IEC 60601-1-6:2006). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CAN/CSA-C22.2 No. 60601-1-6" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). Where differences exist between this consolidated edition and the published edition and its amendments, those documents will take precedence. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Consumer and Commercial Products, under the jurisdiction of the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. Due to the medical content of this Standard, it was also approved by the CSA Technical Committee on Applications of Electricity in Health Care, under the jurisdiction of the CSA Strategic Steering Committee on Health Care Technology and Systems. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object 1.1 * Scope This International Standard specifies a PROCESS for a MANUFACTURER to analyse, specify, develop and evaluate the USABILITY, as it relates to BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT, hereafter referred to as ME EQUIPMENT. This USABILITY ENGINEERING PROCESS assesses and mitigates RISKS caused by USABILITY problems associated with CORRECT USE and USE ERRORS, i.e., NORMAL USE. It can be used to identify but does not assess or mitigate RISKS associated with ABNORMAL USE. If the USABILITY ENGINEERING PROCESS detailed in this collateral standard has been complied with, then the USABILITY of ME EQUIPMENT as it relates to BASIC SAFETY and ESSENTIAL PERFORMANCE is presumed to be acceptable, unless there is OBJECTIVE EVIDENCE to the contrary. NOTE Such OBJECTIVE EVIDENCE can subsequently originate from POST-PRODUCTION surveillance. 1.2 Object The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue l’édition 3.2 consolidée de CAN/CSA-C22.2 nº 60601-1-6, Appareils électromédicaux — Partie 1-6 : Exigences générales pour la sécurité de base et les performances essentielles — Norme collatérale : Aptitude à l’utilisation. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60601-1-6 (édition 3:2010 consolidée par l’amendement 1:2013 et l’amendement 2:2020), qui porte le même titre. Cette norme remplace la deuxième édition publiée en 2008 qui portait la désignation CAN/CSA-C22.2 nº 60601-1-6 (norme IEC 60601-1-6:2006 adoptée). Il fait partie d’une série de normes publiées par Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé « CAN/CSA-C22.2 nº 60601-1-6 ». Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C22.2 nº 60601-1:14, Appareils électromédicaux — Partie 1 : Exigences générales pour la sécurité de base et les performances essentielles (norme IEC 60601-1:2005 adoptée, avec exigences propres au Canada), y compris l’amendement 1:2012). Lorsqu’il y a des différences entre cette édition consolidée et l’édition publiée et ses amendements, ces derniers auront préséance. Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme. Cette norme a été révisée en vue de son adoption au Canada par le Comité technique CSA sur les produits commerciaux et grand public, sous l’autorité du Comité directeur stratégique CSA sur les exigences en matière de sécurité électricité, et a été officiellement approuvée par le Comité technique. En raison de son contenu médical, la norme a également été approuvée par le Comité technique CSA sur les installations électriques dans les établissements de santé, sous l’autorité du Comité directeur stratégique CSA sur la technologie et les systèmes de soins de santé. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes relatives aux Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d'application et objet 1.1 * Domaine d'application La présente Norme internationale spécifie un PROCESSUS destiné à un FABRICANT pour analyser, spécifier, élaborer et évaluer l'APTITUDE A L'UTILISATION, ayant trait à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des APPAREILS ELECTROMEDICAUX, désignés ci-après sous le terme d'APPAREILS EM. Ce PROCESSUS D'INGENIERIE DE L'APTITUDE A L'UTILISATION évalue et réduit les RISQUES provoqués par les problèmes D'APTITUDE A L'UTILISATION associés à une UTILISATION CORRECTE et à des ERREURS D'UTILISATION, c’est-à-dire une UTILISATION NORMALE. Il peut être utilisé pour identifier mais n'évalue pas et ne réduit pas les RISQUES associés à une UTILISATION ANORMALE. Si le PROCESSUS D’INGÉNIERIE D’APTITUDE À L’UTILISATION décrit en détail dans la présente norme collatérale a été respecté, l’APTITUDE À L’UTILISATION des APPAREILS EM, dans la mesure où elle a trait à la SÉCURITÉ DE BASE et aux PERFORMANCES ESSENTIELLES, est présumée acceptable, sauf s'il existe une PREUVE TANGIBLE du contraire. NOTE Cette PREUVE TANGIBLE peut provenir ultérieurement du contrôle de la POSTPRODUCTION. 1.2 Objet La présente norme collatérale est destinée à spécifier des exigences générales qui viennent compléter celles de la norme générale et à servir de base pour les normes particulières.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E62660-2:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 2: Reliability and abuse testing (Adopted IEC 62660-2:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 2 : Essais de fiabilité et de traitement abusif (norme IEC 62660-2:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $225.00 Add to cart -

CSA E61959:14 (R2024) – Secondary cells and batteries containing alkaline or other non-acid electrolytes – Mechanical tests for sealed portable secondary cells and batteries (Adopted IEC 61959:2004, first edition, 2004-01, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide – Essais mécaniques pour accumulateurs portables étanches (norme CEI 61959:2004 adoptée, première édition, 2004-01, avec exigences propres au Canada)
CDN $56.00 Add to cart -

CSA G12:14 (R2024) – Zinc-coated steel wire strand
CDN $136.00 Add to cart -

CSA E61951-2:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
CDN $527.00 Add to cart







