Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 356:26

CSA C22.2 NO. 356:26 – Cables for use in fault-managed power systems

CDN $787.00

Cables for use in fault-managed power systems

SKU: 2432688 Categories: ,

Description

Preface This is the first edition of CSA C22.2 No. 356, Cables for use in fault-managed power systems . This Standard applies to indoor, outdoor, or direct-buried Class 4 cables of Types FM4, FM4P, FM4R, and FM4Z, and rated 450 V peak with a temperature rating of 60 °C to 250 °C for use in fault-managed power systems. These cables may be installed in ordinary, dry, and wet locations, and in plenums and risers, in accordance with the Canadian Electrical Code, Part I. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Cables for Fault-Managed Power Systems, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard applies to indoor, outdoor, or direct-buried Class 4 cables of Types FM4, FM4P, FM4R, and FM4Z, and rated 450 V peak with a temperature rating of 60 °C to 250 °C for use in fault-managed power systems. These cables may be installed in ordinary, dry, and wet locations, and in plenums and risers, in accordance with the Canadian Electrical Code, Part I. This Standard is intended to be used in conjunction with CSA C22.2 No. 0.24. Note: The rated voltages of these cables are not marked. 1.2 Exclusions This Standard does not apply to general requirements for fault-managed power systems, which can be found in CSA C22.2 No. 0.24. 1.3 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard.  Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.4 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. Except for conductor sizes, the values given in parentheses are for information and comparison only.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

49

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of CSA C22.2 No. 356, Cables for use in fault-managed power systems . This Standard applies to indoor, outdoor, or direct-buried Class 4 cables of Types FM4, FM4P, FM4R, and FM4Z, and rated 450 V peak with a temperature rating of 60 °C to 250 °C for use in fault-managed power systems. These cables may be installed in ordinary, dry, and wet locations, and in plenums and risers, in accordance with the Canadian Electrical Code, Part I. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Cables for Fault-Managed Power Systems, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard applies to indoor, outdoor, or direct-buried Class 4 cables of Types FM4, FM4P, FM4R, and FM4Z, and rated 450 V peak with a temperature rating of 60 °C to 250 °C for use in fault-managed power systems. These cables may be installed in ordinary, dry, and wet locations, and in plenums and risers, in accordance with the Canadian Electrical Code, Part I. This Standard is intended to be used in conjunction with CSA C22.2 No. 0.24. Note: The rated voltages of these cables are not marked. 1.2 Exclusions This Standard does not apply to general requirements for fault-managed power systems, which can be found in CSA C22.2 No. 0.24. 1.3 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard.  Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.4 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. Except for conductor sizes, the values given in parentheses are for information and comparison only.

Previous Editions

Can’t find what you are looking for?

Please contact us at: