Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

CSA C22.2 NO. 35:20 (R2024)

CSA C22.2 NO. 35:20 (R2024) – Extra-low-voltage control circuit cable, low-energy control cable, and extra-low-voltage control cable

CDN $365.00

Extra-low-voltage control circuit cable, low-energy control cable, and extra-low-voltage control cable

SKU: 2427126 Categories: ,

Description

Preface This is the seventh edition of CSA C22.2 No. 35, Extra-low-voltage control circuit cable, low-energy control cable, and extra-low-voltage control cable , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code, Part II. It supersedes the previous editions, published in 2009, 1987, 1963, 1947, 1940, and 1937. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Control, Instrument, Communication, and Marine Cables, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for the following types of control cables, rated 30 V maximum, intended for use in extra-low-voltage control circuits in accordance with CSA C22.1, Canadian Electrical Code, Part I: a) Type LVT extra-low-voltage control circuit cables, rated 60 °C maximum; b) Low-energy control cables, rated 105 °C maximum; c) Type ELC extra-low-voltage control cables, rated 60 °C maximum; and d) Type GCS golf course and Type LSS lawn sprinkler, Type LVLL low-voltage landscape lighting, and Type ULEC underground low-energy circuit cables, rated 60 °C maximum. 1.2 Tables 1 and 10 provide summaries of the types of cables covered by this Standard. 1.3 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative non-mandatory) to define their application.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

43

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the seventh edition of CSA C22.2 No. 35, Extra-low-voltage control circuit cable, low-energy control cable, and extra-low-voltage control cable , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code, Part II. It supersedes the previous editions, published in 2009, 1987, 1963, 1947, 1940, and 1937. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Integrated Committee on Control, Instrument, Communication, and Marine Cables, under the jurisdiction of the Technical Committee on Wiring Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies requirements for the following types of control cables, rated 30 V maximum, intended for use in extra-low-voltage control circuits in accordance with CSA C22.1, Canadian Electrical Code, Part I: a) Type LVT extra-low-voltage control circuit cables, rated 60 °C maximum; b) Low-energy control cables, rated 105 °C maximum; c) Type ELC extra-low-voltage control cables, rated 60 °C maximum; and d) Type GCS golf course and Type LSS lawn sprinkler, Type LVLL low-voltage landscape lighting, and Type ULEC underground low-energy circuit cables, rated 60 °C maximum. 1.2 Tables 1 and 10 provide summaries of the types of cables covered by this Standard. 1.3 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative non-mandatory) to define their application.

Previous Editions

Can’t find what you are looking for?

Please contact us at: