
CSA C22.2 NO. 248.3:00 (R2024)
CSA C22.2 NO. 248.3:00 (R2024) – Low-Voltage Fuses – Part 3: Class CA and CB Fuses (Tri-National standard, with UL 248-3 and NMX-J-009/248/3-2000-ANCE)
CDN $420.00
Low-Voltage Fuses – Part 3: Class CA and CB Fuses (Tri-National standard, with UL 248-3 and NMX-J-009/248/3-2000-ANCE)
Description
Preface This is the common UL, CSA, and ANCE Standard for Low-Voltage Fuses – Part 3: Class CA and CB Fuses . This is the second edition of CSA C22.2 No. 248.3-00 (superseding the first edition, published in 1996), the second edition of UL 248-3, and the first edition of NMX-J-009/248/3-2000-ANCE. This Standard was prepared by a Technical Harmonization Committee comprised of members from Underwriters Laboratories, CSA International, the National Association of Standardization and Certification of the Electrical Sector, the end product manufacturers, and material suppliers. The efforts and support of the members of the Technical Harmonization Committee are gratefully acknowledged. This Standard was reviewed by the CSA Subcommittee on Fuses and approved by the Technical Committee on Industrial Products under the jurisdiction of the CSA Strategic Resource Group. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. 1 General NOTE – This Part is intended to be read together with the Standard for Low-Voltage Fuses – Part 1: General Requirements, hereafter referred to as Part 1. The numbering of the Clauses in this Part correspond to like numbered Clauses in Part 1. The requirements of Part 1 apply unless modified by this Part. For Clauses not shown below, refer to the Standard for Low-Voltage Fuses – Part 1: General Requirements, NMX-J-009/248/3-2000-ANCE ¨ CSA C22.2 No. 248.1 / UL 248-1. 1.1 Scope This Part applies to Class CA and CB fuses rated 60 A or less and 600 V ac. DC ratings are optional
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
47
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the common UL, CSA, and ANCE Standard for Low-Voltage Fuses – Part 3: Class CA and CB Fuses . This is the second edition of CSA C22.2 No. 248.3-00 (superseding the first edition, published in 1996), the second edition of UL 248-3, and the first edition of NMX-J-009/248/3-2000-ANCE. This Standard was prepared by a Technical Harmonization Committee comprised of members from Underwriters Laboratories, CSA International, the National Association of Standardization and Certification of the Electrical Sector, the end product manufacturers, and material suppliers. The efforts and support of the members of the Technical Harmonization Committee are gratefully acknowledged. This Standard was reviewed by the CSA Subcommittee on Fuses and approved by the Technical Committee on Industrial Products under the jurisdiction of the CSA Strategic Resource Group. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. 1 General NOTE – This Part is intended to be read together with the Standard for Low-Voltage Fuses – Part 1: General Requirements, hereafter referred to as Part 1. The numbering of the Clauses in this Part correspond to like numbered Clauses in Part 1. The requirements of Part 1 apply unless modified by this Part. For Clauses not shown below, refer to the Standard for Low-Voltage Fuses – Part 1: General Requirements, NMX-J-009/248/3-2000-ANCE ¨ CSA C22.2 No. 248.1 / UL 248-1. 1.1 Scope This Part applies to Class CA and CB fuses rated 60 A or less and 600 V ac. DC ratings are optional
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61347-1:24 – Lamp controlgear – Part 1: General and safety requirements (Adopted IEC 61347-1:2015, edition 3:2015 consolidated with amendment 1:2017, with Canadian deviations) | Appareillages de lampes – Partie 1 : Exigences générales et exigences de sécurité (norme IEC 61347-1:2015 adoptée, édition 3:2015 consolidée par l’amendement 1:2017), avec exigences propres au Canada)
CDN $907.00 Add to cart -

IEEE 844.3-2019/CSA C22.2 NO. 293.3:19 (R2024) – Impedance heating of pipelines and equipment—General, testing, marking, and documentation requirements
CDN $174.00 Add to cart -

CSA G164:26 – Galvanizing of irregularly shaped articles
CDN $142.00 Add to cart -

CSA C22.3 NO. 5.1:93 (R2022) – Recommended practices for electrical protection – Electric contact between overhead supply and communication lines
CDN $149.00 Add to cart







