
CSA C22.2 NO. 180:25
CSA C22.2 NO. 180:25 – Series isolating transformers for airport lighting
CDN $174.00
Series isolating transformers for airport lighting
Description
Preface This is the third edition of CSA C22.2 No. 180, Series isolating transformers for airport lighting . It supersedes the previous editions published in 2013 and 1983. It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. The major changes to this edition include a) updates to reference publications; b) clarification of scope; and c) updates to construction, marking, and testing requirements. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Underground Transformers for Airport Runway Lighting, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to encapsulated isolating transformers for use as a circuit continuity device, intended to be installed in airport field lighting series circuits for use in nonhazardous locations in accordance with the Canadian Electrical Code, Part I. 1.2 This Standard applies to transformers that consist of electrically separated primary and secondary coils that are wound upon a core, the assembly being enclosed in a waterproof case with moulded-on lead connectors. The primary coil is connected into the series circuit and the secondary coil to the light fixture lead by means of plug/receptacle connectors. 1.3 Transformers constructed to meet the requirements of this Standard are suitable for continuous outdoor service in ambient temperatures from a minimum of –55 °C to a maximum of 65 °C and for direct earth burial or placement in a housing (junction box) of an airport lighting raceway system. 1.4 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
21
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the third edition of CSA C22.2 No. 180, Series isolating transformers for airport lighting . It supersedes the previous editions published in 2013 and 1983. It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. The major changes to this edition include a) updates to reference publications; b) clarification of scope; and c) updates to construction, marking, and testing requirements. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Underground Transformers for Airport Runway Lighting, under the jurisdiction of the Technical Committee on Industrial Products and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to encapsulated isolating transformers for use as a circuit continuity device, intended to be installed in airport field lighting series circuits for use in nonhazardous locations in accordance with the Canadian Electrical Code, Part I. 1.2 This Standard applies to transformers that consist of electrically separated primary and secondary coils that are wound upon a core, the assembly being enclosed in a waterproof case with moulded-on lead connectors. The primary coil is connected into the series circuit and the secondary coil to the light fixture lead by means of plug/receptacle connectors. 1.3 Transformers constructed to meet the requirements of this Standard are suitable for continuous outdoor service in ambient temperatures from a minimum of –55 °C to a maximum of 65 °C and for direct earth burial or placement in a housing (junction box) of an airport lighting raceway system. 1.4 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CAN/CSA-E61558-1:12 (R2022) – Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues – Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada)
CDN $630.00 Add to cart -

CSA E62660-2:21 (R2026) – Secondary lithium-ion cells for the propulsion of electric road vehicles – Part 2: Reliability and abuse testing (Adopted IEC 62660-2:2018, second edition, 2018-12, with Canadian deviations) | Éléments d’accumulateurs lithium-ion pour la propulsion des véhicules routiers électriques – Partie 2 : Essais de fiabilité et de traitement abusif (norme IEC 62660-2:2018 adoptée, deuxième édition, 2018-12, avec exigences propres au Canada)
CDN $225.00 Add to cart -

CSA E61951-2:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA E61347-1:24 – Lamp controlgear – Part 1: General and safety requirements (Adopted IEC 61347-1:2015, edition 3:2015 consolidated with amendment 1:2017, with Canadian deviations) | Appareillages de lampes – Partie 1 : Exigences générales et exigences de sécurité (norme IEC 61347-1:2015 adoptée, édition 3:2015 consolidée par l’amendement 1:2017), avec exigences propres au Canada)
CDN $907.00 Add to cart







