Preface This is the second edition of CSA C2.1, Single-phase and three-phase liquid-filled distribution transformers. It supersedes the previous edition published in 2006 and previous editions of CSA C2, Single-Phase and Three-Phase Liquid-filled Distribution Transformers, Types ONAN and LNAN, published in 1991, 1982, 1976, 1969, 1959, 1944, 1928, and 1920. This edition includes requirements for single-phase, single-bushing, 60 Hz distribution transformers suitable for direct pole mounting and designed for operation on an effectively grounded wye system, Type ONAN, rated at 167 kVA or below, up to 34.5 kV system nominal voltage. Changes to this edition include updates to various clauses, tables, figures, and annexes to reflect minimum industry requirements. This Standard specifies the requirements for distribution transformers intended primarily for operation by electric utilities. The operation of transformers complying with this Standard by other than an electric utility could be subject to additional requirements by the electrical inspection regulatory authority having jurisdiction. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of Alectra Utilities, Electricity Canada (EC), EPCOR, FortisAlberta, FortisBC, Hydro One, Hydro-Québec, IFD Corp., K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland and Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard was prepared by the Subcommittee on Overhead and Pad-Mounted Distribution Transformers, under the jurisdiction of the Technical Committee on Distribution Transformers and the Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard specifies the requirements for distribution transformers except for those distribution transformers covered by CSA C2.2, CSA C227.3, and CSA C227.4. Note: The operation of transformers complying with this Standard by other than an electric utility might be subject to additional requirements by the electrical inspection authority having jurisdiction. 1.2 Ratings This Standard applies to single- and three-phase, 60 Hz, liquid-filled distribution transformers rated at 1000 kVA or below for single-phase, and at 3000 kVA or below for three-phase, up to 34.5 kV system nominal voltage. 1.3 Performance characteristics This Standard includes voltage ratings, kVA ratings, certain mechanical characteristics, and test procedures. It also includes the following performance characteristics: energy efficiency (in accordance with CSA C802.1), temperature rise, loading capabilities, sound level, and radio influence voltage (RIV). 1.4 Self-protected transformers This Standard also applies to self-protected transformers with the exception of protective equipment. 1.5 Exceptions Except as specified by other CSA Standards, this Standard does not apply to auto-, testing, dry-type, welding, furnace, rectifier, network, subway, or special-purpose transformers, or to step-voltage regulators. 1.6 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.7 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition
Not found
Published Date
2026-10-05
Status
Not found
Pages
74
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment
Abstract
Preface This is the second edition of CSA C2.1, Single-phase and three-phase liquid-filled distribution transformers. It supersedes the previous edition published in 2006 and previous editions of CSA C2, Single-Phase and Three-Phase Liquid-filled Distribution Transformers, Types ONAN and LNAN, published in 1991, 1982, 1976, 1969, 1959, 1944, 1928, and 1920. This edition includes requirements for single-phase, single-bushing, 60 Hz distribution transformers suitable for direct pole mounting and designed for operation on an effectively grounded wye system, Type ONAN, rated at 167 kVA or below, up to 34.5 kV system nominal voltage. Changes to this edition include updates to various clauses, tables, figures, and annexes to reflect minimum industry requirements. This Standard specifies the requirements for distribution transformers intended primarily for operation by electric utilities. The operation of transformers complying with this Standard by other than an electric utility could be subject to additional requirements by the electrical inspection regulatory authority having jurisdiction. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of Alectra Utilities, Electricity Canada (EC), EPCOR, FortisAlberta, FortisBC, Hydro One, Hydro-Québec, IFD Corp., K-Line Insulators Ltd., Maritime Electric, NB Power, Newfoundland and Labrador Hydro, Newfoundland Power, Nova Scotia Power, S&C Electric Canada Ltd., Schneider Electric Canada Inc., Toronto Hydro, and Utilities Standards Forum (USF). This Standard was prepared by the Subcommittee on Overhead and Pad-Mounted Distribution Transformers, under the jurisdiction of the Technical Committee on Distribution Transformers and the Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Inclusions This Standard specifies the requirements for distribution transformers except for those distribution transformers covered by CSA C2.2, CSA C227.3, and CSA C227.4. Note: The operation of transformers complying with this Standard by other than an electric utility might be subject to additional requirements by the electrical inspection authority having jurisdiction. 1.2 Ratings This Standard applies to single- and three-phase, 60 Hz, liquid-filled distribution transformers rated at 1000 kVA or below for single-phase, and at 3000 kVA or below for three-phase, up to 34.5 kV system nominal voltage. 1.3 Performance characteristics This Standard includes voltage ratings, kVA ratings, certain mechanical characteristics, and test procedures. It also includes the following performance characteristics: energy efficiency (in accordance with CSA C802.1), temperature rise, loading capabilities, sound level, and radio influence voltage (RIV). 1.4 Self-protected transformers This Standard also applies to self-protected transformers with the exception of protective equipment. 1.5 Exceptions Except as specified by other CSA Standards, this Standard does not apply to auto-, testing, dry-type, welding, furnace, rectifier, network, subway, or special-purpose transformers, or to step-voltage regulators. 1.6 Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. 1.7 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-

CSA E61558-2-13:25 – Safety of transformers, reactors, power supply units and combinations thereof — Part 2-13: Particular requirements and tests for auto-transformers and power supply units incorporating auto-transformers for general applications (Adopted IEC 61558-2-13:2022, third edition, 2022-10, with Canadian deviations) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et combinaisons de ces éléments — Partie 2-13 : Exigences particulières et essais pour les autotransformateurs et les blocs d’alimentation qui incorporent des autotransformateurs pour applications d’ordre général (norme IEC 61558-2-13:2022 adoptée, troisième édition, 2022-10, avec exigences propres au Canada)
CDN $205.00 Add to cart -

CSA E61951-2:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride (Adopted IEC 61951-2:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 2 : Nickel-métal hydrure (norme IEC 61951-2:2017 adoptée, quatrième édition, 2017-03, avec exigences propres au Canada)
CDN $527.00 Add to cart -

CSA G164:26 – Galvanizing of irregularly shaped articles
CDN $142.00 Add to cart -

CSA E61951-1:21 (R2026) – Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 1: Nickel-cadmium (Adopted IEC 61951:2017, fourth edition, 2017-03, with Canadian deviations) | Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Accumulateurs étanches pour applications portables — Partie 1 : Nickel-cadmium (norme IEC 61951-1:2017 adoptée, quatrième édition, 2017-03), avec exigences propres au Canada)
CDN $527.00 Add to cart