Sky Bear Technical Standards - Home
Search
×
FR

Placeholder headline

This is just a placeholder headline

CSA A123.21:26 – Standard test method for the dynamic wind uplift resistance of membrane-roofing systems

$

236

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.2-03 (R2023) – Asphalt-coated roofing sheets

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.23-15 (R2025) – Product specification for polymer-modified bitumen sheet, prefabricated and reinforced

$

118

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.24:21 (R2026) – Standard test method for wind resistance of vegetated roof assembly

$

161

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.25:18 (R2023) – Asphalt core boards used in roofing

$

197

BUY NOW

Placeholder headline

This is just a placeholder headline

A123.3-05 (R2020) – Asphalt saturated organic roofing felt

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CAN/CSA-A123.4-04 (R2023) – Asphalt for constructing built-up roof coverings and waterproofing systems

$

150

BUY NOW

Placeholder headline

This is just a placeholder headline

CSA A123.5:16 (R2020) – Asphalt shingles made from glass felt and surfaced with mineral granules

$

197

BUY NOW

ASSE 1013-26/CSA B64.4:26

ASSE 1013-26/CSA B64.4:26 – Reduced pressure principle (RP) backflow prevention assemblies

CDN $221.00

Reduced pressure principle (RP) backflow prevention assemblies

Description

Preface This is the first edition of ASSE 1013/CSA B64.4, Reduced pressure principle (RP) backflow prevention assemblies . It supersedes ASSE 1013, Performance Requirements for Principle Backflow Prevention Assemblies, published in 2021, and CSA B64.4, Reduced pressure principle (RP) backflow preventers, published in 2021. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the ASSE/CSA Harmonization Task Group on Reduced Pressure Principle Backflow Prevention Assemblies, under the jurisdiction of the ASSE Product Standards Committee and the CSA Technical Committee on Backflow Preventers and Water Pressure Reducing Valves. The CSA Technical Committee operates under the jurisdiction of the CSA Strategic Steering Committee on Construction and Civil Infrastructure. This Standard has been formally approved by the ASSE Product Standards Committee and the CSA Technical Committee on Backflow Preventers and Water Pressure Reducing Valves. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This Standard was approved as an American National Standard by the American National Standards Institute. Scope 1.1 General This Standard covers reduced pressure principle (RP) backflow prevention assemblies (herein referred to as the “assembly”) that are used in potable water supply systems to prevent cross-connections. 1.2 Sizes This Standard applies to nominal assembly sizes of 1/4, 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 4, 6, 8, 10, 12, 14, and 16 in (DN8, DN10, DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN150, D200, D250, D300, D350, and DN400). 1.3 Application RP assemblies are intended for use in the isolation of high or severe hazards where contaminated water can flow back into a potable water distribution system. 1.4 Description RP assemblies consist of two independently acting check valves, internally force loaded to a normally closed position and separated by an intermediate chamber (or zone) in which there is a hydraulically operated relief means for venting to the atmosphere, and internally force loaded to a normally open position. These assemblies are designed to operate under continuous pressure conditions. The assembly includes two properly located, tightly closing shut-off valves and properly located test cocks as per Clauses 4.4.4.5 and 4.4.4.4.1. 1.5 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.6 Units of measurement SI units are the units of record in Canada. In this Standard, inch/pound units are shown in parentheses. The values stated in each measurement system are equivalent in application; however, each system is to be used independently. Combining values from the two measurement systems can result in non-conformance with this Standard. All references to gallons are to U.S. gallons.

Edition

Not found

Published Date

2026-10-05

Status

Not found

Pages

50

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

Preface This is the first edition of ASSE 1013/CSA B64.4, Reduced pressure principle (RP) backflow prevention assemblies . It supersedes ASSE 1013, Performance Requirements for Principle Backflow Prevention Assemblies, published in 2021, and CSA B64.4, Reduced pressure principle (RP) backflow preventers, published in 2021. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the ASSE/CSA Harmonization Task Group on Reduced Pressure Principle Backflow Prevention Assemblies, under the jurisdiction of the ASSE Product Standards Committee and the CSA Technical Committee on Backflow Preventers and Water Pressure Reducing Valves. The CSA Technical Committee operates under the jurisdiction of the CSA Strategic Steering Committee on Construction and Civil Infrastructure. This Standard has been formally approved by the ASSE Product Standards Committee and the CSA Technical Committee on Backflow Preventers and Water Pressure Reducing Valves. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This Standard was approved as an American National Standard by the American National Standards Institute. Scope 1.1 General This Standard covers reduced pressure principle (RP) backflow prevention assemblies (herein referred to as the "assembly") that are used in potable water supply systems to prevent cross-connections. 1.2 Sizes This Standard applies to nominal assembly sizes of 1/4, 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 4, 6, 8, 10, 12, 14, and 16 in (DN8, DN10, DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN150, D200, D250, D300, D350, and DN400). 1.3 Application RP assemblies are intended for use in the isolation of high or severe hazards where contaminated water can flow back into a potable water distribution system. 1.4 Description RP assemblies consist of two independently acting check valves, internally force loaded to a normally closed position and separated by an intermediate chamber (or zone) in which there is a hydraulically operated relief means for venting to the atmosphere, and internally force loaded to a normally open position. These assemblies are designed to operate under continuous pressure conditions. The assembly includes two properly located, tightly closing shut-off valves and properly located test cocks as per Clauses 4.4.4.5 and 4.4.4.4.1. 1.5 Terminology In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.6 Units of measurement SI units are the units of record in Canada. In this Standard, inch/pound units are shown in parentheses. The values stated in each measurement system are equivalent in application; however, each system is to be used independently. Combining values from the two measurement systems can result in non-conformance with this Standard. All references to gallons are to U.S. gallons.

Previous Editions

Can’t find what you are looking for?

Please contact us at: