REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API MPMS CH 22.6: Testing Protocols for Gas Chromatographs : Reaffirmed

$

192

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1174: Onshore Hazardous Liquid Pipeline Emergency Preparedness and Response : Reaffirmed

$

182

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 624: Type Testing of Rising Stem Valves Equipped with Flexible Graphite Packing for Fugitive

$

171

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 20G: Welding Services for Equipment used in the Petroleum and Natural Gas Industry : Reaffirmed

$

164

BUY NOW

Placeholder headline

This is just a placeholder headline

API STD 624: Errata 2

$

0.00

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems

$

167

BUY NOW

ISO 13004:2022

ISO 13004:2022 Sterilization of health care products – Radiation – Substantiation of selected sterilization dose: Method VDmaxSD

CDN $351.00

SKU: 0a4ccf84dbba Category:

Description

This document describes a method for substantiating a selected sterilization dose of 17,5 kGy, 20 kGy, 22,5 kGy, 27,5 kGy, 30 kGy, 32,5 kGy or 35 kGy that achieves a sterility assurance level (SAL) of 10−6 or less for radiation sterilization of health care products. This document also specifies a method of sterilization dose audit used to demonstrate the continued effectiveness of the substantiated sterilization dose.

NOTE 1   Selection and substantiation of the sterilization dose is used to meet the requirements for establishing the sterilization dose within process definition in ISO 11137‑1.

This document does not apply to other sterilization doses than the substantiation of a selected sterilization dose of 17,5 kGy, 20 kGy, 22,5 kGy, 27,5 kGy, 30 kGy, 32,5 kGy or 35 kGy. The method is not used for the substantiation of a selected sterilization dose if the average bioburden of the entire product item exceeds the limit specified for the selected sterilization dose (see Table 3).

NOTE 2   The methods for substantiation of selected sterilization doses of 25 kGy and 15 kGy are not included in this document. They are described in ISO 11137‑2.

If the decision is made to use this method of sterilization dose establishment, the method is intended to be followed in accordance with the requirements (shall) and guidance (should) stipulated herein.

Edition

1

Published Date

2022-10-07

Status

PUBLISHED

Pages

54

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document describes a method for substantiating a selected sterilization dose of 17,5 kGy, 20 kGy, 22,5 kGy, 27,5 kGy, 30 kGy, 32,5 kGy or 35 kGy that achieves a sterility assurance level (SAL) of 10−6 or less for radiation sterilization of health care products. This document also specifies a method of sterilization dose audit used to demonstrate the continued effectiveness of the substantiated sterilization dose.

NOTE 1   Selection and substantiation of the sterilization dose is used to meet the requirements for establishing the sterilization dose within process definition in ISO 11137‑1.

This document does not apply to other sterilization doses than the substantiation of a selected sterilization dose of 17,5 kGy, 20 kGy, 22,5 kGy, 27,5 kGy, 30 kGy, 32,5 kGy or 35 kGy. The method is not used for the substantiation of a selected sterilization dose if the average bioburden of the entire product item exceeds the limit specified for the selected sterilization dose (see Table 3).

NOTE 2   The methods for substantiation of selected sterilization doses of 25 kGy and 15 kGy are not included in this document. They are described in ISO 11137‑2.

If the decision is made to use this method of sterilization dose establishment, the method is intended to be followed in accordance with the requirements (shall) and guidance (should) stipulated herein.