REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems

$

167

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 1173: Pipeline Safety Management Systems : Errata 1

$

0

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 11S2: Electric Submersible Pump Testing: Edition 3

$

158

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

ISO 16000:2024

ISO 16000:2024 Indoor air – Part 9: Determination of the emission of volatile organic compounds from samples of building products and furnishing – Emission test chamber method

CDN $173.00

SKU: 054acb66a814 Categories: ,

Description

This document specifies a general laboratory test method for the determination of the area specific emission rate of volatile organic compounds (VOCs) from samples of newly produced building products or furnishing under defined climate conditions. The method can also, in principle, be applied to samples of aged products. The emission data obtained can be used to calculate concentrations in a model room (see Table B.1).

This document is applicable to various emission test chambers used for the determination of the emission of VOCs from building products or furnishing.

This document is also applicable to samples of wood-based panels and other building products, in order to determine the emission rate of formaldehyde.

NOTE            In principle, this document can be applied to the study of any gas phase emissions from samples of building products and furnishing.

Edition

2

Published Date

2024-03-20

Status

PUBLISHED

Pages

16

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies a general laboratory test method for the determination of the area specific emission rate of volatile organic compounds (VOCs) from samples of newly produced building products or furnishing under defined climate conditions. The method can also, in principle, be applied to samples of aged products. The emission data obtained can be used to calculate concentrations in a model room (see Table B.1).

This document is applicable to various emission test chambers used for the determination of the emission of VOCs from building products or furnishing.

This document is also applicable to samples of wood-based panels and other building products, in order to determine the emission rate of formaldehyde.

NOTE            In principle, this document can be applied to the study of any gas phase emissions from samples of building products and furnishing.